MESSAGE
BOARD
FREE
USER
MANUALS
ALARM
COMPANIES
Alarm Installation
P. I.
Patrol Services
Central Stations
Fire Alarm
Locksmith
ALARM
EQUIPMENT
DSC
ADEMCO
PARADOX
FBI
Wireless_Devices
Central
Station
CCTV
Fire Alarm
Gas/CO-Detectors
Dual Detectors
Glass Break Detector
PIR (motion detector)
Environmental
Magnetic Contacts
Transformers
Batteries
Siren
Discontinued
Items
POINTS
of
INTEREST
Metric Imperial
US
Conversion
Frequently
Asked Question
Statistics
How Devices
Works
Y2K
FALSE
ALARMS
False Alarms Fees
British Columbia
California
Other US Cities
FREE LINK
TO
AlarmsBC


CONTACT US
|
Environmental Alarms
|
 |
|
|
|
A wide variety of agricultural and environmental monitoring devices. AC
power loss, high and low temperature, Fluid and water levels, fire and heat,
along with gas detectors.
Monitoring these devices,24/7 , whether its AC loss
or high temperature in barns for poultry, high temperature in freezers for ice
cream or just fire and gas monitoring , assure you peace of mind.
These devices could be installed and monitored as an integral
part of your security system, or as a standalone installation. |
Temp Alarms Humidity Alert
WaterBug Alert Power-out Alert
Enviro Alert
Sensors
HOW THESE SYSTEMS WORKS : Analog alarm inputs typically measure a range of values, unlike on/off
discrete alarms (example AC power loss).
A common example of an analog application is the measurement of temperature.
If you have analog alarm values to measure, you need to define the thresholds at
which your monitoring system will take action.
For example, suppose you are measuring the temperature of a remote site.
Building temperatures range from 10 to 120 degrees Fahrenheit. Under normal
conditions, the building's heating and cooling system will keep the temperature
within an acceptable range. To take advantage of multiple analog values, you
might set up 4 different threshold values like below:
- When the temperature is below 30 degrees, page a technician and notify the
Network Operations Center (NOC). A value this low might indicate that the
heater is not working at all.
- When the temperature is below 50 degrees, notify the NOC. This may
indicate that the heater is not functioning properly.
- When the temperature is above 80 degrees, notify the NOC. This may
indicate that the air conditioning unit is not functioning properly.
- When the temperature is above 100 degrees, page a technician, notify the
NOC, and open a vent (via derived controls). This may indicate that the air
conditioning unit is not functioning at all.
ENVIRO-ALERT
|
EA-200

Dual Zone Digital Environmental Monitoring Alarm
This advanced monitoring and alarm device provides precise
monitoring of critical environments by utilizing an on-board
temperature sensor or attaching any one of the remote temperature,
humidity and water sensing probes. Receive dual zone coverage from
simultaneous operation of the local and remote sensors. If either zone
being monitored deviates from the preset limits, a relay output sends
a signal to an appropriate warning system.
FEATURES
- Defrost time delay up to 120 minutes
- Easy to read large LCD display
- Eight event alarm memory with time and date
- Auxiliary output relay for local audible alarm
- Auxiliary alarm silence feature with 10 minute timer
- Each zone has offset calibration adjustment
- Temperature & humidity Hi / Lo set points
- Output relays can be configured to be initially energized or
de-energized
- Tamper proof lock setting
- Snap fit mounting base with main housing for easy access
- Plug in terminal strip connectors for easier wire termination
- Zones being monitored are displayed every few seconds
- Each Zone can be configured with:
- Display F°, C°, % (Humidity) or Water Drop icon
- Zone configuration retained in memory if power is lost
SPECIFICATIONS
|
EA-400
 Four Zone
Digital Environmental Monitoring Alarm
Monitor four zones with any combination of a remote temperature,
humidity or water sensing probe. If temperatures and humidity deviate
from the preset limits or water forms a bridge between the contacts on
the WaterBug® sensor the designated relay for each zone will activate
an alarm, dialer, transmitter, etc.
FEATURES
- Simultaneous operation of all four zones
- Defrost time delay up to 120 minutes
- Easy to read large LCD display
- Eight event alarm memory with time and date
- Auxiliary output relay for local audible alarm
- Auxiliary alarm silence feature with 10 minute timer
- Each zone has offset calibration adjustment
- Temperature & humidity Hi / Lo set points
- Output relays can be configured to be initially energized or
de-energized
- Tamper proof lock setting
- Snap fit mounting base with main housing for easy access
- Plug in terminal strip connectors for easier wire termination
- Zones being monitored are displayed every few seconds
- Display F°, C°, % (Humidity) or Water Drop icon
- Zone configuration retained in memory if power is lost
SPECIFICATIONS
- Dimensions: 6.0” x 4.75 x 1.25
- Weight: .60 lb
- Lo & Hi Limit Adjust Range: -58 to 299° F
- Input Voltage: 12 VDC @ <200mA
- Number of sensor inputs: 4
- Unit Operating Range: +32 to 122° F
- Alarm Outputs: 4 - SPDT Relays (Configurable)
- Auxiliary Audible Alarm Output: 1 - SPDT Relays (Non-configurable)
- Case Material: ABS
- Sensor Type/Connection:
- Temperature:2-wire; maximum 304 m (1000 ft.) cabling length
- Humidity:3-wire; maximum 304 m (1000 ft.) cabling length
- Water Presence: 2-wire; maximum 304 m (1000 ft.) cabling length
- Minimum Span Between High and Low Limits
|
SENSORS for EA-200/ EA-400
|

M-001-0081 = SS High Temp Thermistor Probe
(32 to 299°
F)
(no cable)

M-001-0082 = SS Low Temp Thermistor Probe
(-58 to 158° F)
(no cable)
|
1106 = Standard Temp Sensor (no cable)
+32*to +220* F (0* to +105* C)
M001-0006 = WaterBug® Sensor
(no cable)
HA-III Humidity Range: 5% to 95%RH.

|
PLEASE E-MAIL IF
YOU NEED OTHER SENSORS
 |
- 110 volt AC powered
- Compact design plugs into standard ac outlet for mounting
- Fixed 3 to 8 minute alarm delay, eliminates nuisance alarms
- Provides SPST output through attached 15 foot 2 wire cable
- Dimensions: 2.25" x 2" x 3" (5.7 cm x 5.1 cm x 7.6 cm)
- Weight: 5.6 oz. (159 g) (with 15 feet of cord)
- Shipping Weight: 9.3 oz. (264 g)
- Application: Any standard 2-3 blade 110 volt outlet
- Mounting: Permanent mounting is available with standard eyelet and
included mounting screw
- Color: Beige and brown
- Switch Contact Rating: 0.5 A @ 30 VRMS (not for direct high voltage
switching)
- Operating Temperature: -30? to +90? F (-34? to +32? C)
|

AC
Power Loss alert PS-110
The model PS-110 is a compact power outage monitoring device
that easily plugs into any 110 VAC receptacle outlet for operation. Simply
connect the SPST output alarm cable to an alarm system, telephone dialer
or other emergency equipment and prompt notification of the outage will
occur after the 3-8 minute delay. This delay guards against nuisance
alarms.
|

WB-200
WATERBUG  Waterbug -
12 or 24 VAC or VDC
Electronic water detection at its best!
The model WB-200 operates on 12 or 24 Volt AC/DC and has a form C relay output
that can be connected to alarm panels, bells, dialers, etc. The unit can monitor
up to as many as six sensor probes, up to 100 feet away. Each sensor probe has
two contacts. When a film of water forms a bridge between these contacts, the
unit senses this and triggers the alarm output. The sensor will not alarm due to
condensation or high humidity. One standard surface sensor is included with the
unit.
Accessory Options:
- Standard surface sensor - P/N 1040
- Under carpet sensor - P/N 1041
- Wall Transformer P/N 1111
- Voltage: 110 VAC - 12VDC regulated, 300mA.
Specifications:
- Console Size: 5" x 2.44" x 1.25" (12.7 cm x 6.2 cm x 3.18 cm)
- Probe Size (standard P/N #1040): 2" x 3" x 0.88" (5.1 cm x 7.6 cm x
2.2 cm)
- Probe Size (under carpet P/N #1041): 2" x 3" x 0.18" (5.1 cm x 7.6 cm
x 0.5 cm)
- Power Requirements (resting state): 12V or 24V AC or DC
- Power Requirements (alarm condition): 5mA @ 12V or 24V AC, or 13.5mA @
12V or 24V DC
- Sensitivity: Will not alarm due to high humidity or condensation
- Operating Temperature: Control and Probe 32? to +140? F (0? to +60? C)
- Outputs: Form C (SPDT) 1 Amp @ 24Vac, 1 Amp @ 30 VDC (not for direct
high voltage switching)
- Recomended Dist. Between Probes & Console: 1-2 probes: 200ft (61 m)
max. Ç 3 or more probes: 100ft (30.5 m) per probe
- Recommended Max. Probes Per Console
|
Typical Applications:
- Residential or Vacation Homes
- Basement Sump Pumps
- Commercial Buildings
- Office and Computer Areas
- Unattended Buildings
- Greenhouses & Animal Buildings
- All Drain Areas
- Sprinkler Systems
Features:
- Versatile 12 or 24 Volt AC/DC power for operation
- No false alarms due to condensation or humidity
- Can monitor up to 6 sensor probes - up to 100 feet away
- Provides (1) form "C" contact closure output for alarm
- Easy surface mount installation
- One year parts and labor; subject to conditions of limited warranty.
|

TEMPERATURE
ALARM Mechanical Fixed Temp Alert
TA-40
Simple solution to avoid frost shattered pipes and the water
damage that can follow.
The simple TA-40 Temp switch is the perfect solution for simple low cost
protection in homes, mountain cabins, or any unattended building. The unit
will activate a hardwire or wireless alarm system if the temperature should
fall below 40F from its fixed internal sensor. The TA-40 provides positive
protection and peace-of-mind to residential and business property owners
concerned about the risk of frost shattered pipes and the water damage that
follows. An added advantage is the unit's compact size, which enables it to
be installed in virtually any setting without being noticed. Contacts above
40 F are normally closed and below 40 F are normally open.
Features:
- Requires no power for operation
- Fixed 39F low set point
- Compact size
- Provides (1) dry contact opening output for alarm
- Easy surface mount - two screw - installation
- One year parts and labor; subject to conditions of limited warranty
|

Specifications:
-
Operating Temperature Range: -40 to +212 F (-40 to
+100 C)
-
Contacts: Open at £ 39.5 +/-5.4 F (£ 4 +/-3 C)
-
Contact Output Rating: Voltage £ to 24V AC/DC ‚ Current £
200mA (not for direct high voltage switching): Recommended Sensor Cable
-
18 to 24 gauge: Case Material
-
ABS plastic rated 94V-0: Dimensions: 2.5" x 0.8" x .55"
(6.4 cm x 2 cm x 1.4 cm)
-
Weight: 3.0 oz. (85 g)
-
Color: Off-white
-
Mounting: 2 screw holes (0.165" dia.)
-
Master Pack Weight: Carton of 12: 1 pound (0.45kg)
-
Warranty: 1 year Limited
|
Mechanical Temp Alert
TA-1
The economical TA-1 Mechanical Temp Alert adds reliable and
economical temperature protection to your residential or commercial security
system. The design can be used anywhere the monitoring of high and low
temperature limits is critical. The unit measures temperatures from -30 to
+130F (-34 to +54C). Simply select an acceptable temperature range by
setting the adjustable high and low limits. If temperatures in the monitored
area rise above or fall below the set limits, the temperature indicator
contacts one of the preset limit arms providing a dry contact closure, which
can like a switch be used to turn on an existing alarm panel, telephone
communicator, or wireless alarm system.
Features:
- Requires no power for operation
- Independently adjustable high and low set points
- Easily to read temp indicator in F or C
- Provides (1) dry contact closure output for alarm
- Easy surface mount installation
- One year parts and labor; subject to conditions of limited warranty.
|

Specifications:
- Low Limit Adjust Range: -30 to +90 F (-34 to +32 C)
- High Limit Adjust Range *: -10 to +130 F (-12 to +54 C)
- Minimum Span (Rec. dist. between high & low set points.): 10 F (5.6
C)
- Temp/RH Accuracy of Probes: +/-3 F (+/-1.7 C)
- Temp Response Time: TC= 14 Minutes
- Temp Sensing Element: Bi-metallic coil
- Outputs (not for high voltage use): Gold Plated N/O dry contacts
- Contact Output Rating: 12VDC @ 50mA (not for direct high voltage
switching)
- Control Box Material: ABS
- Weight: 6.0 oz. (170 g)
- Dimensions: 6.25" x 3.75" x 1" (15.9 cm x 9.5 cm x 2.5 cm)
- Mounting: 2 Key slots in rear panel
|
Mechanical Temp Alert
TA-2HL
The economical TA-2HL Mechanical Temp Alert adds reliable
and economical temperature protection to your residential or commercial
security system. The design can be used anywhere the monitoring of high and
low temperature limits is critical. The unit is a special version, which
will enable you to separately zone out high and low temperature alarm
signals. Simply select an acceptable temperature range by setting the
adjustable high and low limits from -30 to +130F (-34 to +54C). If
temperatures in the monitored area rise above or fall below the set limits,
the temperature indicator contacts one of the preset limit arms providing a
dry contact closure, which can like a switch be used to turn on an existing
alarm panel, telephone communicator, or wireless alarm system.
The 1" profile and custom graphics which make it ideal for placement in
residential homes, businesses, or other settings where a highly professional
appearance is important. In addition, the unit's 15' length of signal cable
exits through the back panel so that no wires are visible when the
installation is complete. By wiring several Temp Alerts in parallel, it is
possible to monitor temperatures in an entire complex.
Features:
- Requires no power for operation
- Independently adjustable high and low set points
- Easily to read temp indicator in F or C
- Provides (2) dry contact closure outputs 1-high alarm, 1-low alarm
- Easy surface mount installation
- One year parts and labor; subject to conditions of limited warranty.
|

Specifications:
- Low Limit Adjust Range: -30 to +90 F (-34 to +32 C)
- High Limit Adjust Range : -10 to +130 F (-12 to +54 C)
- Minimum Span (Rec. dist. between high & low set points.): 10 F (5.6
C)
- Temp/RH Accuracy of Probes: +/-3 F (+/-1.7 C)
- Temp Response Time: TC= 14 Minutes
- Temp Sensing Element: Bi-metallic coil
- Outputs (not for high voltage use): Gold Plated N/O dry contacts
- Contact Output Rating: 12VDC @ 50mA (not for direct high voltage
switching)
- Control Box Material: ABS
- Weight: 6.0 oz. (170 g)
- Dimensions: 6.25" x 3.75" x 1" (15.9 cm x 9.5 cm x 2.5 cm)
- Mounting: 2 Key slots in rear panel
|
|
AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES
=CENTRAL STATIONS
PROTOCOLS
=SOFTWARE
=INSTALLATION
TIPS
and
NOTES
=FORMS
=PRODUCTS
OVERVIEW
=TECH
SUPPORT PHONE NUMBERS
WEB HOSTING
=DATA
CENTER and
CONNECTIVITY
=VIRTUAL PACKAGES
DETAILS
=VIRTUAL
PACKAGES PRICES
=WEB CONTROL PANEL
=POLICIES
LINKS TO
RELATED SITES
JOKES
DAILY NEWS
CANADA MAP
GLOSSARY
SEARCHING
WWW
UNIVERSAL CURRENCY CONVERTER
CONTACT US
|