ALARMSBC LOGO---back to home page

EQUIPMENT SHOWCASE

MESSAGE
BOARD


FREE USER
MANUALS

English
International
Chinese


ALARM
COMPANIES

Canada
USA
UK
Australia
New Zeeland


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

-Wireless Devices 
-Central  Station
Equipment

-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector 
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren  

Promotion
Special Orders
&
ON SALE

Items


POINTS
of
INTEREST
 

-Metric Imperial US Conversion
-Frequently Asked Question
-Security Licence
-Statistics
-Standards
-How  Devices Works
-Tips to Improve Security
-Y2K


FALSE ALARMS

-False Alarms Fees
-British Columbia
-California
-Other US Cities


CENTRAL STATION


INSTALLATION
&
SERVICE


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


FREE  LINK
TO
 AlarmsBC


JOKES


DAILY NEWS


CANADA
MAP

 


BRITISH
COLUMBIA
MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


Our Guestbook


CONTACT US

 


Environmental Alarms
 

A wide variety of agricultural and environmental monitoring devices. AC power loss, high and low temperature, Fluid and water levels, fire and heat, along with gas detectors.

Monitoring these devices,24/7 , whether its AC loss or high temperature in barns for poultry, high temperature in freezers for ice cream or just fire and gas monitoring , assure you peace of mind.

These devices could be installed and monitored as an integral part of your security system, or as a standalone installation.

  Temp Alarms     Humidity Alert      WaterBug Alert      Power-out Alert      Enviro Alert     Sensors


HOW THESE SYSTEMS WORKS :

Analog alarm inputs typically measure a range of values, unlike on/off discrete alarms (example AC power loss).
A common example of an analog application is the measurement of temperature.
If you have analog alarm values to measure, you need to define the thresholds at which your monitoring system will take action.

For example, suppose you are measuring the temperature of a remote site. Building temperatures range from 10 to 120 degrees Fahrenheit. Under normal conditions, the building's heating and cooling system will keep the temperature within an acceptable range. To take advantage of multiple analog values, you might set up 4 different threshold values like below:

  1. When the temperature is below 30 degrees, page a technician and notify the Network Operations Center (NOC). A value this low might indicate that the heater is not working at all.

  2. When the temperature is below 50 degrees, notify the NOC. This may indicate that the heater is not functioning properly.

  3. When the temperature is above 80 degrees, notify the NOC. This may indicate that the air conditioning unit is not functioning properly.

  4. When the temperature is above 100 degrees, page a technician, notify the NOC, and open a vent (via derived controls). This may indicate that the air conditioning unit is not functioning at all.

 


ENVIRO-ALERT

EA-200

ea200 enviro by winland
Dual Zone Digital Environmental Monitoring Alarm
 

This advanced monitoring and alarm device provides precise monitoring of critical environments by utilizing an on-board temperature sensor or attaching any one of the remote temperature, humidity and water sensing probes. Receive dual zone coverage from simultaneous operation of the local and remote sensors. If either zone being monitored deviates from the preset limits, a relay output sends a signal to an appropriate warning system.


FEATURES

  • Defrost time delay up to 120 minutes
  • Easy to read large LCD display
  • Eight event alarm memory with time and date
  • Auxiliary output relay for local audible alarm
  • Auxiliary alarm silence feature with 10 minute timer
  • Each zone has offset calibration adjustment
  • Temperature & humidity Hi / Lo set points
  • Output relays can be configured to be initially energized or de-energized
  • Tamper proof lock setting
  • Snap fit mounting base with main housing for easy access
  • Plug in terminal strip connectors for easier wire termination
  • Zones being monitored are displayed every few seconds
  • Each Zone can be configured with:
  • Display F, C, % (Humidity) or Water Drop icon
  • Zone configuration retained in memory if power is lost

SPECIFICATIONS

  • Dimensions: 6.0" x 4.75 x 1.25
  • Weight: .55 lb
  • Lo & Hi Limit Adjust Range: -58 to 299 F
  • Input Voltage: 12 VDC @ <120mA
  • Remote sensor inputs: 1
  • On-Board sensor: 1
  • Unit Operating Range: +32 to 122 F
  • Alarm Outputs: 2 - SPDT Relays (Configurable)
  • Auxiliary Audible Alarm Output: 1 - SPDT Relays (Non-configurable)
  • Case Material: ABS
  • Sensor Type/Connection:
    • Temperature:2-wire; maximum 304 m (1000 ft.) cabling length
    • Humidity:3-wire; maximum 304 m (1000 ft.) cabling length
    • Water Presence: 2-wire; maximum 304 m (1000 ft.) cabling length
  • Minimum Span Between High and Low Limits

    • 4 C ( F)

    • 4% RH

 

EA-400


Four Zone Digital Environmental Monitoring Alarm
 

Monitor four zones with any combination of a remote temperature, humidity or water sensing probe. If temperatures and humidity deviate from the preset limits or water forms a bridge between the contacts on the WaterBug sensor the designated relay for each zone will activate an alarm, dialer, transmitter, etc.
 

 

FEATURES

  • Simultaneous operation of all four zones
  • Defrost time delay up to 120 minutes
  • Easy to read large LCD display
  • Eight event alarm memory with time and date
  • Auxiliary output relay for local audible alarm
  • Auxiliary alarm silence feature with 10 minute timer
  • Each zone has offset calibration adjustment
  • Temperature & humidity Hi / Lo set points
  • Output relays can be configured to be initially energized or de-energized
  • Tamper proof lock setting
  • Snap fit mounting base with main housing for easy access
  • Plug in terminal strip connectors for easier wire termination
  • Zones being monitored are displayed every few seconds
  • Display F, C, % (Humidity) or Water Drop icon
  • Zone configuration retained in memory if power is lost

SPECIFICATIONS

  • Dimensions: 6.0 x 4.75 x 1.25
  • Weight: .60 lb
  • Lo & Hi Limit Adjust Range: -58 to 299 F
  • Input Voltage: 12 VDC @ <200mA
  • Number of sensor inputs: 4
  • Unit Operating Range: +32 to 122 F
  • Alarm Outputs: 4 - SPDT Relays (Configurable)
  • Auxiliary Audible Alarm Output: 1 - SPDT Relays (Non-configurable)
  • Case Material: ABS
  • Sensor Type/Connection:
    • Temperature:2-wire; maximum 304 m (1000 ft.) cabling length
    • Humidity:3-wire; maximum 304 m (1000 ft.) cabling length
    • Water Presence: 2-wire; maximum 304 m (1000 ft.) cabling length
  • Minimum Span Between High and Low Limits
    • 4 C ( F)

    • 4% RH

 


SENSORS for EA-200/ EA-400

 

hi temp probe winland
M-001-0081 =
SS High Temp Thermistor Probe
(32 to 299 F)
(no cable)



M-001-0082
= SS Low Temp Thermistor Probe
(-58 to 158 F)
(no cable)


 

1106 = Standard Temp Sensor (no cable)
+32*to +220* F (0* to +105* C)

 winland 1106


M001-0106 = WaterBug Sensor
(no cable)


HA-III  Humidity Range: 5% to 95%RH.

humidity sensor 1128/ hiii


 

TOP


AC POWER LOSS ALERT

  • 110 volt AC powered
  • Compact design plugs into standard ac outlet for mounting
  • Fixed 3 to 8 minute alarm delay, eliminates nuisance alarms
  • Provides SPST output through attached 15 foot 2 wire cable
  • Dimensions: 2.25" x 2" x 3" (5.7 cm x 5.1 cm x 7.6 cm)
  • Weight: 5.6 oz. (159 g) (with 15 feet of cord)
  • Shipping Weight: 9.3 oz. (264 g)
  • Application: Any standard 2-3 blade 110 volt outlet
  • Mounting: Permanent mounting is available with standard eyelet and included mounting screw
  • Color: Beige and brown
  • Switch Contact Rating: 0.5 A @ 30 VRMS (not for direct high voltage switching)
  • Operating Temperature: -30? to +90? F (-34? to +32? C)

 


AC Power Loss alert  PS-110

The model PS-110 is a compact power outage monitoring device that easily plugs into any 110 VAC receptacle outlet for operation. Simply connect the SPST output alarm cable to an alarm system, telephone dialer or other emergency equipment and prompt notification of the outage will occur after the 3-8 minute delay. This delay guards against nuisance alarms.

 

TOP


WB-200

Electronic water detection at its best!

Waterbug - 12 or 24 VAC or VDC
 

include 1 x 1040sensor


 

Standard surface sensor
winland 1040


Under carpet sensor
winland 1041


 


Wall Transformer
transformer 1111 winland
 


 
1175
remote buzzer winland 1175

 

BZ-1 REMOTE Buzzer
 

BZ-1 REMOTE BUZZER

 

 


The model WB-200 operates on 12 or 24 Volt AC/DC and has a form C relay output that can be connected to alarm panels, bells, dialers, etc. The unit can monitor up to as many as six sensor probes, up to 100 feet away. Each sensor probe has two contacts. When a film of water forms a bridge between these contacts, the unit senses this and triggers the alarm output. The sensor will not alarm due to condensation or high humidity. One standard surface sensor is included with the unit.

Accessory Options:
  • Standard surface sensor - P/N 1040 M-001-0106
  • Under carpet sensor - P/N 1041 M-001-0107
  • Wall Transformer P/N 1111
  • Voltage: 110 VAC - 12VDC regulated, 300mA.

Specifications:

  • Console Size: 5" x 2.44" x 1.25" (12.7 cm x 6.2 cm x 3.18 cm)
  • Probe Size (standard P/N #1040): 2" x 3" x 0.88" (5.1 cm x 7.6 cm x 2.2 cm)
  • Probe Size (under carpet P/N #1041): 2" x 3" x 0.18" (5.1 cm x 7.6 cm x 0.5 cm)
  • Power Requirements (resting state): 12V or 24V AC or DC
  • Power Requirements (alarm condition): 5mA @ 12V or 24V AC, or 13.5mA @ 12V or 24V DC
  • Sensitivity: Will not alarm due to high humidity or condensation
  • Operating Temperature: Control and Probe 32? to +140? F (0? to +60? C)
  • Outputs: Form C (SPDT) 1 Amp @ 24Vac, 1 Amp @ 30 VDC (not for direct high voltage switching)
  • Recomended Dist. Between Probes & Console: 1-2 probes: 200ft (61 m) max. 3 or more probes: 100ft (30.5 m) per probe
  • Recommended Max. Probes Per Console

 

Typical Applications:
  • Residential or Vacation Homes
  • Basement Sump Pumps
  • Commercial Buildings
  • Office and Computer Areas
  • Unattended Buildings
  • Greenhouses & Animal Buildings
  • All Drain Areas
  • Sprinkler Systems

Features:

  • Versatile 12 or 24 Volt AC/DC power for operation
  • No false alarms due to condensation or humidity
  • Can monitor up to 6 sensor probes - up to 100 feet away
  • Provides (1) form "C" contact closure output for alarm
  • Easy surface mount installation
  • One year parts and labor; subject to conditions of limited warranty.

 

TOP


TEMPERATURE ALARM

Mechanical Fixed Temp Alert TA-40
Simple solution to avoid frost shattered pipes and the water damage that can follow.

The simple TA-40 Temp switch is the perfect solution for simple low cost protection in homes, mountain cabins, or any unattended building. The unit will activate a hardwire or wireless alarm system if the temperature should fall below 40F from its fixed internal sensor. The TA-40 provides positive protection and peace-of-mind to residential and business property owners concerned about the risk of frost shattered pipes and the water damage that follows. An added advantage is the unit's compact size, which enables it to be installed in virtually any setting without being noticed. Contacts above 40 F are normally closed and below 40 F are normally open.

Features:

  • Requires no power for operation
  • Fixed 39F low set point
  • Compact size
  • Provides (1) dry contact opening output for alarm
  • Easy surface mount - two screw - installation
  • One year parts and labor; subject to conditions of limited warranty

ta40 temperature alert

  Specifications:

  • Operating Temperature Range: -40 to +212 F (-40 to +100 C)

  • Contacts: Open at 39.5 +/-5.4 F ( 4 +/-3 C)

  • Contact Output Rating: Voltage to 24V AC/DC Current 200mA (not for direct high voltage switching): Recommended Sensor Cable

  • 18 to 24 gauge: Case Material

  • ABS plastic rated 94V-0: Dimensions: 2.5" x 0.8" x .55" (6.4 cm x 2 cm x 1.4 cm)

  • Weight: 3.0 oz. (85 g)

  • Color: Off-white

  • Mounting: 2 screw holes (0.165" dia.)

  • Master Pack Weight: Carton of 12: 1 pound (0.45kg)

  • Warranty: 1 year Limited


Mechanical Temp Alert TA-1

The economical TA-1 Mechanical Temp Alert adds reliable and economical temperature protection to your residential or commercial security system. The design can be used anywhere the monitoring of high and low temperature limits is critical. The unit measures temperatures from -30 to +130F (-34 to +54C). Simply select an acceptable temperature range by setting the adjustable high and low limits. If temperatures in the monitored area rise above or fall below the set limits, the temperature indicator contacts one of the preset limit arms providing a dry contact closure, which can like a switch be used to turn on an existing alarm panel, telephone communicator, or wireless alarm system.
 

Features:

  • Requires no power for operation
  • Independently adjustable high and low set points
  • Easily to read temp indicator in F or C
  • Provides (1) dry contact closure output for alarm
  • Easy surface mount installation
  • One year parts and labor; subject to conditions of limited warranty.

 

ta1 temperature alert

Specifications:

  • Low Limit Adjust Range: -30 to +90 F (-34 to +32 C)
  • High Limit Adjust Range *: -10 to +130 F (-12 to +54 C)
  • Minimum Span (Rec. dist. between high & low set points.): 10 F (5.6 C)
  • Temp/RH Accuracy of Probes: +/-3 F (+/-1.7 C)
  • Temp Response Time: TC= 14 Minutes
  • Temp Sensing Element: Bi-metallic coil
  • Outputs (not for high voltage use): Gold Plated N/O dry contacts
  • Contact Output Rating: 12VDC @ 50mA (not for direct high voltage switching)
  • Control Box Material: ABS
  • Weight: 6.0 oz. (170 g)
  • Dimensions: 6.25" x 3.75" x 1" (15.9 cm x 9.5 cm x 2.5 cm)
  • Mounting: 2 Key slots in rear panel

 

TOP

Mechanical Temp Alert TA-2HL

The economical TA-2HL Mechanical Temp Alert adds reliable and economical temperature protection to your residential or commercial security system. The design can be used anywhere the monitoring of high and low temperature limits is critical. The unit is a special version, which will enable you to separately zone out high and low temperature alarm signals. Simply select an acceptable temperature range by setting the adjustable high and low limits from -30 to +130F (-34 to +54C). If temperatures in the monitored area rise above or fall below the set limits, the temperature indicator contacts one of the preset limit arms providing a dry contact closure, which can like a switch be used to turn on an existing alarm panel, telephone communicator, or wireless alarm system.


The 1" profile and custom graphics which make it ideal for placement in residential homes, businesses, or other settings where a highly professional appearance is important. In addition, the unit's 15' length of signal cable exits through the back panel so that no wires are visible when the installation is complete. By wiring several Temp Alerts in parallel, it is possible to monitor temperatures in an entire complex.
 

Features:

  • Requires no power for operation
  • Independently adjustable high and low set points
  • Easily to read temp indicator in F or C
  • Provides (2) dry contact closure outputs 1-high alarm, 1-low alarm
  • Easy surface mount installation
  • One year parts and labor; subject to conditions of limited warranty.

ta40 temperature alert

 

Specifications:

  • Low Limit Adjust Range: -30 to +90 F (-34 to +32 C)
  • High Limit Adjust Range :  -10 to +130 F (-12 to +54 C)
  • Minimum Span (Rec. dist. between high & low set points.): 10 F (5.6 C)
  • Temp/RH Accuracy of Probes: +/-3 F (+/-1.7 C)
  • Temp Response Time: TC= 14 Minutes
  • Temp Sensing Element: Bi-metallic coil
  • Outputs (not for high voltage use): Gold Plated N/O dry contacts
  • Contact Output Rating: 12VDC @ 50mA (not for direct high voltage switching)
  • Control Box Material: ABS
  • Weight: 6.0 oz. (170 g)
  • Dimensions: 6.25" x 3.75" x 1" (15.9 cm x 9.5 cm x 2.5 cm)
  • Mounting: 2 Key slots in rear panel
 

TOP

HUMIDITY ALERT
 
Economical humidity protection.
 
 

 

The model HA-1 is a stand-alone humidity-monitoring device requiring no power for operation. Simply set the single high or low adjustable set point within 20% to 80% range. If the monitored humidity set point is met or exceeded, a SPDT micro-switch will activate any type of alarm panel, telephone dialer, wireless alarm system, etc.

1190 WINLAND HUMIDITY CONTROL


 

  
Copyright 1997 - 2010

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 17-Jan-2010
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 *  etc...  etc....

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US