ALARMSBC LOGO---back to home page

EQUIPMENT  DSC


MESSAGE
BOARD


FREE USER
MANUALS

English
International
Chinese


ALARM
COMPANIES

Canada
USA
UK
Australia
New Zeeland


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

-Wireless Devices 
-Central  Station
Equipment

-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector 
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren  

Promotion
Special Orders
&
ON SALE

Items


POINTS
of
INTEREST
 

-Metric Imperial US Conversion
-Frequently Asked Question
-Security Licence
-Statistics
-Standards
-How  Devices Works
-Tips to Improve Security
-Y2K


FALSE ALARMS

-False Alarms Fees
-British Columbia
-California
-Other US Cities


CENTRAL STATION


INSTALLATION
&
SERVICE


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


FREE  LINK
TO
 AlarmsBC


JOKES


DAILY NEWS


CANADA
MAP

 


BRITISH
COLUMBIA
MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


Our Guestbook


CONTACT US

 




A NEW CONTROL PANEL

  Pictures PCB Boards     DIAGRAM

   

New power series control panels are backward compatible with all of the previous power seris generation modules and keypads. They feature a new board design with new firmware and over 100 new program features


 

POWER 432   A NEW GENERATION  (PC-580)

4-32 Zone Control Panel 

  • 4 hardwire zones on main control panel 

  • 8 keypad input zones (1 per keypad)

  • 32 wireless zones using PC5132 wireless receiver

  • up to 8 hardwired and 4 wireless keypads

  • 3 hardwired keypads available…

    -

    PC1555RKZ eight zone LED keypad with zone input

    -

    PC5508Z eight zone LED keypad with zone input

    -

    PC5516Z sixteen zone LED keypad with zone input

    -

    PC5532Z thirty two zone LED keypad with zone input

    -

    LCD5500Z alphanumeric keypad with zone input

  • WLS910 - wireless hand-held keypad

  • added wireless control is provided by…

    WLS908 - wireless panic pendant 

    WLS909 - wireless key 

  • PGM1 and PGM2 with 20 programmable options

  • supports all major formats including SIA and Contact ID

  • LINKS™ 1000 cellular communication

  • LINKS™ 2150 long range radio communication

  • DVACS using PC5400DV-SG in place of PC5400 printer module

  • event-initiated personal paging

  • 3 phone numbers (3rd backs up primary number)

  • 2 account numbers 

UParrow.gif (1001 bytes)


POWER 632   A NEW GENERATION  (PC-1555)

6-32 Zone Control Panel  

  Pictures PCB Boards     DIAGRAM



  • 6 hardwire zones on main control panel 

  • 8 keypad input zones (1 per keypad)

  • 32 wireless zones using PC5132 wireless receiver

  • up to 8 hardwired and 4 wireless keypads

  • hardwired keypads   compatible:

    PC1555RKZ eight zone LED keypad with zone input
    PC5508Z eight zone LED keypad with zone input
    PC5516Z sixteen zone LED keypad with zone input
    PC5532Z thirty two zone LED keypad with zone input
    LCD5500Z alphanumeric keypad with zone input
    LCD5501Z Fix LCD keypad with zone input

  • WLS910 - wireless hand-held keypad

  • added wireless control is provided by…
    WLS908 - wireless panic pendant 
    WLS909 - wireless key 

Advanced Communications

Supports all major formats including SIA and Contact ID
Skyroute™ and GSM1000™ cellular communication
Event initiated personal paging
3 phone numbers (3rd backs up primary number)
2 account numbers

System Operation

• 38 - 4 or 6 digit access codes
- 32 user codes, 1 system master code, 2 partition master codes,2 duress codes, and 1 maintenance code

• Keypad lockout

- panel can be programmed to lockout keypad if a series of incorrect access code entries are made

• ‘Quick Arm’ and ‘Quick Exit’
- allows users to arm and exit easily

• ‘Stay/Away’ zones and ‘Stay’ arming

- security of perimeter arming while premise is occupied

• Door chime

- programmable by zone
- monitor a door by having keypad beep when the door is opened and again when door is closed

• 128 event buffer

- all events automatically stored with time and date stamp to buffer
- events can be printed on-site using the PC5400 serial printer interface module, viewed through an LCD Keypad, or viewed and printed via PC using DLS software


 

False Alarm Prevention Features

Audible exit delay
Audible exit fault
Urgency on entry delay
‘Quick Exit’
Swinger shutdown
Cross zone alarm
Communication delay
Arm/Disarm bell squawk
Recent closing transmission
Rotating keypress buffer

 Local PCLINK™ and remote upload/download capability

Program system using DLS software (version 6.5 or newer) via direct PCLINK connection to control panel or remotely via modem
View status and trouble conditions, and system 128 event buffer
Remote access can be controlled by owner to prevent unauthorized access to system
User call-up feature

Full Supervision
The system continuously monitors the following trouble conditions:

AC power failure
Fire trouble
Trouble by zone
Telephone line trouble
Bell output trouble
Tamper by zone
Low battery
Loss of internal clock
Fail to communicate
Aux power supply fault
Module fault (supervisory or tamper)

 

Integrated Voice Assisted Security & Automation
ESCORT5580TC Voice Assisted Security & Automation Control Module

• Turns any touch-tone phone into a fully functional keypad with Global and Partition control
• Built-in power line interface for control of 32 X-10 automation control devices

16 schedules with On Time, Off Time, and Day of Week
 8 user controlled automation modes
Full range of dimming levels for lighting control
Event activated control for any PGM output supported by the main panel

• An extensive library of voice prompts for security and automation operation, programming, and system status feedback

250 system words for pre-programmed system functions
240 word library for user programmable voice prompts for Automation Item Labels, Automation Mode Labels, Partition Labels, and Zone Labels

• Program up to 6 words per voice label
• Powerful ‘say number’ command can announce numbers from 0-999 in three different ways
• Supports up to four EMS-100 thermostats
• EMS-100 has 4 temperature control modes :

day occupancy mode
night occupancy mode
auxiliary occupancy mode
away occupancy mode

• Each thermostat optionally supports:

up to six EMS-IDS remote indoor temperature sensors for interior temperature averaging
one EMS-ODS outdoor temperature sensor for display of outdoor temperature

• Connect up to 1000' (305m) from control panel via KEYBUS
• Specifications
- Current draw: 150mA @ 12VDC

 

 

UParrow.gif (1001 bytes)


POWER 832  A NEW GENERATION  (PC-5010)

  • PC5010 main control panel - alarm only

  • PC5015 main control panel - alarm plus Downlook video capability

POWER 832
  Pictures PCB Boards     DIAGRAM


Power 832 Security System It used to be that a burglar alarm was all you needed to feel safe. Well, times have changed. And so have your security options. In keeping with new times and new technologies.  Introducing Power 832...from DSC. A security system that is more than a burglar alarm. easy-to-use, affordable system that will offer you peace of mind.

Home Automation Imagine a security system that will control your appliance. With this system you can adjust your heating, control the light, open your garage door, unlock your gates, and turn on your sprinkler system...all with just a simple phone call. With the Power 832, you can even program your system to turn on the lights in the event of a burglar or fire alarm. More great ways to stay safe from DSC.

Paging Can't be home to greet the kids after school? Would like to track the number of hours your housekeeper spends in you home? Have peace of mind knowing that your system will page you the minute your kids walk through the door. Or when your housekeeper leaves for the day. Power 832 offers different codes for different needs to suit your own personal lifestyle.

Remote Telephone Access When your on vacation or on business travel, there's no need to worry about your home. with Power 832, you can check on your system from anywhere in the world. It's worldwide telephone assess, you instantly know if your system is armed or if there have been any alarms. Talk about peace of mind.

7 Station Intercom Power 832 offers so many new and exciting way to keep you and your family safe. Our 7 station intercom allows you to listen to the baby sleeping in the nursery, and communicate with your children in the playroom while you work in your 2nd floor office. Talk to people at your door without having to open it. All this security....and hands-free too!

Smoke Alarm DSC's smoke alarm detector provides superior sensitivity to all types of smoke and in linked to alarm the Power 832 in case of smoke detection.

UParrow.gif (1001 bytes)

  • support up to 32 zones using  any combination of up to :

    -

    8 hardwire zones on main panel

    -

    8 hardwire zones using PC5108L video matrix module (on PC5015 only)

    -

    4 general purpose hardwire zones and 2 waterflow hardwire zones using PC5700 fire module (in Canada only)

    -

    24 hardwire zones using PC5108 eight zone expander modules

    -

    8 keypad zones

    -

    32 wireless zones using PC5132 wireless receiver module

  • zone programming

    -

    all zones programmable as burglary or fire

    -

    zone options include : Normally Closed loop, Single End of Line (EOL) resistor, and Double EOL resistor *
    * keypad zones cannot be programmed as fire zones and cannot support Double EOL resistor supervision

    -

    27 programmable zone types, 8 programmable zone options

  • audible alarm output

    -

    supervised bell output - 700 mA @ 12VDC, PTC protected, current limited at 3 A

    -

    steady, pulsed, temporal pattern, or strobe fire output

    -

    additional supervised siren output is available using PC5204 power supply module

  • programmable voltage outputs

    -

    1 high current 300mA PGM… can also be used for 2 wire smoke with a maximum of 20 detectors at 15mA per detector

    -

    1 low current 50mA PGM

    -

    8 additional low current PGM outputs using PC5208 module

    -

    4 additional high current PGM outputs using PC5204 module

    -

    24 programmable options

  • local PCLINK™ and remote upload/download capability

    -

    program system using DLS software and direct PC connection to control panel or via remote PC over telephone line

    -

    view status and trouble conditions, and system 128 event buffer

    -

    remote access can be controlled by owner to prevent unauthorized access to system

  • power supply

    -

    550mA @ 12.5VDC auxiliary power (400mA for UL applications)

    -

    positive temperature coefficient (PTC) protected battery, AUX, and Bell output

    -

    electronic protection of KEYBUS

    -

    supervision of AC power loss, low battery, auxiliary power failure

    -

    internal clock locked to AC power frequency

  • EEPROM memory

    -

    will not lose programming or system status on complete AC and battery failure

  • digital communicator

    -

    supports all major formats including SIA & Contact ID

    -

    supports LINKS1000™ cellular communications

    -

    supports LINKS2150™ and LINKS2450™ long range radio communications

    -

    3 phone numbers (3rd backs up primary)

    -

    2 account numbers

    -

    DTMF or pulse dialing

    -

    DPDT line seizure

    -

    anti-jam feature

    -

    split reporting of selected events to each telephone number

    -

    event initiated personal paging

  • battery required : 12V, 4 Ah, rechargeable sealed lead acid

  • transformer required : 16.5VAC, 40VA

  • 2 system partitions… 2 account numbers
    - each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features
    38 - 4 or 6 digit access codes
    - 32 user codes, 1 system master code, 2 partition master codes, 2 duress codes, and 1 maintenance code
    automatic arming by partition
    - each partition may be programmed to auto-arm at its own time each day
    keypad lockout
    - panel can be programmed to lockout keypad if a series of incorrect access code entries are made
    'quick arm' and 'quick exit'
    - allows users to arm and exit easily
    'stay/away' zones and 'stay' arming
    - security of perimeter arming while premise is occupied
    door chime
    - programmable by zone
    - monitor a door by having keypad beep when the door is opened and again when door is closed
    128 event buffer
    - all events automatically stored with time and date stamp to buffer
    - events can be printed on-site using the PC5400 serial printer interface module, viewed through an LCD Keypad, or viewed and printed via PC using DLS software

UParrow.gif (1001 bytes)

 

 
Full Supervision : The system continuously monitors the following trouble conditions : AC power failure
 

  trouble by zone
fire trouble
telephone line trouble
low battery
bell output trouble
loss of internal clock
tamper by zone
fail to communicate
aux power supply fault
module fault (supervisory or tamper)
camera troubles
(on PC5015 with Downlook)

False Alarm Prevention Features

audible exit delay
audible exit fault
quick exit
urgency on entry delay
swinger shutdown
cross zone alarm
recent closing transmission
burglary verified timer *
double hit timer *
communication delay
rotating keypress buffer
arm/disarm bell squawk


* on PC5015 v2.2x and higher

Advanced Communications

supports all major formats including SIA and Contact ID
LINKS1000™ cellular communication
LINKS2150™ and LINKS2450™ long range radio communication
DVACS communication using PC5400 or PC5720 modules
Downlook video transmission using PC5108L module on Power832 PC5015 main control panel
event initiated personal paging
3 phone numbers (3rd backs up primary number)
2 account numbers

Integrated Intercom Audio

supports Central Station Two Way Voice and Home Intercom features using PC5928 audio interface module, PC5921 intercom stations, and PC5904 two way listen-in stations

Integrated CCTV

supports Downlook still frame video transmission using PC5108L module on Power832 PC5015 main control panel
provides local VCR/monitor video switching for 8 cameras

Integrated Voice Assisted Security & Home Automation

Escort5580 & 5580TC provide voice assisted security and automation control for up to 32 X-10 devices plus thermostat control on 5580TC


POWER 864   A NEW GENERATION
(PC-5020)

TECHNICALSPECIFICATIONS


  Pictures PCB Boards     DIAGRAM


UParrow.gif (1001 bytes)

 

  
© Copyright 1997 - 2010

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 04-Jan-2010
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 *  etc...  etc....

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US