MESSAGE
BOARD
FREE
USER
MANUALS
English
International
Chinese
ALARM
COMPANIES
Canada
USA
UK
Australia
New Zeeland
ALARM
EQUIPMENT
DSC
ADEMCO
PARADOX
FBI
-Wireless
Devices
-Central
Station
Equipment
-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren
Promotion
Special Orders
&
ON SALE
Items
POINTS
of
INTEREST
-Metric Imperial
US
Conversion
-Frequently
Asked Question
-Security Licence
-Statistics
-Standards
-How Devices
Works
-Tips to Improve Security
-Y2K
FALSE
ALARMS
-False Alarms Fees
-British Columbia
-California
-Other US Cities
CENTRAL STATION
INSTALLATION
&
SERVICE

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES
=CENTRAL STATIONS
PROTOCOLS
=SOFTWARE
=INSTALLATION
TIPS
and
NOTES
=FORMS
=PRODUCTS
OVERVIEW
=TECH
SUPPORT PHONE NUMBERS
WEB HOSTING
=DATA
CENTER and
CONNECTIVITY
=VIRTUAL PACKAGES
DETAILS
=VIRTUAL
PACKAGES PRICES
=WEB CONTROL PANEL
=POLICIES
LINKS TO
RELATED SITES
FREE LINK
TO
AlarmsBC
JOKES
DAILY NEWS
CANADA
MAP
BRITISH
COLUMBIA
MAP
GLOSSARY
SEARCHING
WWW
UNIVERSAL CURRENCY CONVERTER


CONTACT US
|

A NEW CONTROL PANEL
Pictures PCB Boards DIAGRAM
New power
series control panels are backward compatible with all of the
previous power seris generation modules and keypads. They feature
a new board design with new firmware and over 100 new program
features
POWER
432 A NEW GENERATION (PC-580)
4-32 Zone Control Panel 
-
4 hardwire zones on
main control panel
-
8 keypad input zones
(1 per keypad)
-
32 wireless zones
using PC5132 wireless receiver
-
up to 8 hardwired and
4 wireless keypads
-
3 hardwired keypads
available…
|
-
|
PC1555RKZ
eight zone LED keypad with zone input
|
|
-
|
PC5508Z
eight zone LED keypad with zone input
|
|
-
|
PC5516Z
sixteen zone LED keypad with zone input
|
|
-
|
PC5532Z
thirty two zone LED keypad with zone input
|
|
-
|
LCD5500Z
alphanumeric keypad with zone input
|
-
supports all major
formats including SIA and Contact ID
-
LINKS™ 1000 cellular
communication
-
LINKS™ 2150 long
range radio communication
-
DVACS using
PC5400DV-SG in place of PC5400 printer module
-
event-initiated
personal paging
-
3 phone numbers (3rd
backs up primary number)
-
2 account numbers

POWER
632 A NEW GENERATION (PC-1555)

6-32 Zone Control Panel
Pictures PCB Boards DIAGRAM
-
6 hardwire zones on
main control panel
-
8 keypad input zones
(1 per keypad)
-
32 wireless zones
using PC5132 wireless receiver
-
up to 8
hardwired and 4 wireless keypads
-
hardwired
keypads
compatible:
PC1555RKZ eight zone LED keypad with zone input
PC5508Z eight zone LED keypad with zone input
PC5516Z sixteen zone LED keypad with zone input
PC5532Z thirty two zone LED keypad with zone input
LCD5500Z alphanumeric keypad with zone input
LCD5501Z Fix LCD keypad with zone input
Advanced Communications
Supports all major formats including SIA and Contact ID
Skyroute™ and GSM1000™ cellular communication
Event initiated personal paging
3 phone numbers (3rd backs up primary number)
2 account numbers
|
System Operation
• 38 - 4 or 6 digit access codes
- 32 user codes, 1 system master code, 2 partition master codes,2 duress
codes, and 1 maintenance code
• Keypad lockout
- panel can be programmed to lockout keypad if a series of incorrect access
code entries are made
• ‘Quick Arm’ and ‘Quick Exit’
- allows users to arm and exit easily
• ‘Stay/Away’ zones and ‘Stay’ arming
- security of perimeter arming while premise is occupied
• Door chime
- programmable by zone
- monitor a door by having keypad beep when the door is opened and again
when door is closed
• 128 event buffer
- all events automatically stored with time and date stamp to buffer
- events can be printed on-site using the PC5400 serial printer interface
module, viewed through an LCD Keypad, or viewed and printed via PC using DLS
software
|
False Alarm Prevention
Features
Audible exit delay
Audible exit fault
Urgency on entry delay
‘Quick Exit’
Swinger shutdown
Cross zone alarm
Communication delay
Arm/Disarm bell squawk
Recent closing transmission
Rotating keypress buffer
Local PCLINK™ and remote
upload/download capability
Program system using DLS software
(version 6.5 or newer) via direct PCLINK connection to control panel or
remotely via modem
View status and trouble conditions, and system 128 event buffer
Remote access can be controlled by owner to prevent unauthorized access to
system
User call-up feature
Full Supervision
The system continuously monitors the following trouble conditions:
AC power failure
Fire trouble
Trouble by zone
Telephone line trouble
Bell output trouble
Tamper by zone
Low battery
Loss of internal clock
Fail to communicate
Aux power supply fault
Module fault (supervisory or tamper)
|
Integrated Voice Assisted Security &
Automation
ESCORT5580TC Voice Assisted Security & Automation Control Module
• Turns any touch-tone phone into a fully functional keypad
with Global and Partition control
• Built-in power line interface for control of 32 X-10
automation control devices
16 schedules with On Time, Off Time, and Day of Week
8 user controlled automation modes
Full range of dimming levels for lighting control
Event activated control for any PGM output supported by
the main panel
• An extensive library of voice prompts for security and automation operation, programming, and system status feedback
250 system words for pre-programmed system functions
240 word library for user programmable voice prompts for Automation Item Labels, Automation Mode Labels, Partition Labels, and Zone Labels
• Program up to 6 words per voice label
• Powerful ‘say number’ command can announce numbers from 0-999 in three different ways
• Supports up to four EMS-100 thermostats
• EMS-100 has 4 temperature control modes :
day occupancy mode
night occupancy mode
auxiliary occupancy mode
away occupancy mode
• Each thermostat optionally supports:
up to six EMS-IDS remote indoor temperature sensors for interior temperature averaging
one EMS-ODS outdoor temperature sensor for display of outdoor temperature
• Connect up to 1000' (305m) from control panel via KEYBUS
• Specifications
- Current draw: 150mA @ 12VDC
|

POWER 832 A NEW GENERATION
(PC-5010)

Pictures PCB Boards DIAGRAM
Power 832 Security System It used to be that a burglar alarm was all
you needed to feel safe. Well, times have changed. And so have your
security options. In keeping with new times and new technologies. Introducing Power 832...from DSC. A security system that is more than a
burglar alarm. easy-to-use, affordable system that will offer you peace of
mind.
Home Automation Imagine a security system that will control your
appliance. With this system you can adjust your heating, control the
light, open your garage door, unlock your gates, and turn on your
sprinkler system...all with just a simple phone call. With the Power 832,
you can even program your system to turn on the lights in the event of a
burglar or fire alarm. More great ways to stay safe from DSC.
Paging Can't
be home to greet the kids after school? Would like to track the number of
hours your housekeeper spends in you home? Have peace of mind knowing that
your system will page you the minute your kids walk through the door. Or
when your housekeeper leaves for the day. Power 832 offers different codes
for different needs to suit your own personal lifestyle.
Remote Telephone Access When
your on vacation or on business travel, there's no need to worry about
your home. with Power 832, you can check on your system from anywhere in
the world. It's worldwide telephone assess, you instantly know if your
system is armed or if there have been any alarms. Talk about peace of
mind.
7 Station Intercom Power 832 offers so many new and exciting way to keep you
and your family safe. Our 7 station intercom allows you to listen to the
baby sleeping in the nursery, and communicate with your children in the
playroom while you work in your 2nd floor office. Talk to people at your
door without having to open it. All this security....and hands-free too!
Smoke Alarm DSC's
smoke alarm detector provides superior sensitivity to all types of smoke
and in linked to alarm the Power 832 in case of smoke detection.

-
support up to 32 zones using any combination of
up to :
|
-
|
8 hardwire zones
on main panel
|
|
-
|
8 hardwire zones
using PC5108L video matrix module (on PC5015 only)
|
|
-
|
4 general
purpose hardwire zones and 2 waterflow hardwire zones using
PC5700 fire module (in Canada only)
|
|
-
|
24 hardwire
zones using PC5108 eight zone expander modules
|
|
-
|
8 keypad zones
|
|
-
|
32 wireless
zones using PC5132 wireless receiver module
|
-
zone programming
|
-
|
all zones
programmable as burglary or fire
|
|
-
|
zone options
include : Normally Closed loop, Single End of Line (EOL)
resistor, and Double EOL resistor *
* keypad zones
cannot be programmed as fire zones and cannot support Double
EOL resistor supervision
|
|
-
|
27 programmable
zone types, 8 programmable zone options
|
-
audible alarm output
|
-
|
supervised bell
output - 700 mA @ 12VDC, PTC protected, current limited at 3
A
|
|
-
|
steady, pulsed,
temporal pattern, or strobe fire output
|
|
-
|
additional
supervised siren output is available using PC5204 power
supply module
|
-
programmable voltage outputs
|
-
|
1 high current
300mA PGM… can also be used for 2 wire smoke with a
maximum of 20 detectors at 15mA per detector
|
|
-
|
1 low current
50mA PGM
|
|
-
|
8 additional low
current PGM outputs using PC5208 module
|
|
-
|
4 additional
high current PGM outputs using PC5204 module
|
|
-
|
24 programmable
options
|
-
local PCLINK™ and remote upload/download
capability
|
-
|
program system
using DLS software and direct PC connection to control panel
or via remote PC over telephone line
|
|
-
|
view status and
trouble conditions, and system 128 event buffer
|
|
-
|
remote access
can be controlled by owner to prevent unauthorized access to
system
|
-
power supply
|
-
|
550mA @ 12.5VDC
auxiliary power (400mA for UL applications)
|
|
-
|
positive
temperature coefficient (PTC) protected battery, AUX, and
Bell output
|
|
-
|
electronic
protection of KEYBUS
|
|
-
|
supervision of
AC power loss, low battery, auxiliary power failure
|
|
-
|
internal clock
locked to AC power frequency
|
-
EEPROM memory
|
-
|
will not lose
programming or system status on complete AC and battery
failure
|
-
digital communicator
|
-
|
supports all
major formats including SIA & Contact ID
|
|
-
|
supports
LINKS1000™ cellular communications
|
|
-
|
supports
LINKS2150™ and LINKS2450™ long range radio
communications
|
|
-
|
3 phone numbers
(3rd backs up primary)
|
|
-
|
2 account
numbers
|
|
-
|
DTMF or pulse
dialing
|
|
-
|
DPDT line
seizure
|
|
-
|
anti-jam feature
|
|
-
|
split reporting
of selected events to each telephone number
|
|
-
|
event initiated
personal paging
|
-
battery required : 12V, 4 Ah, rechargeable
sealed lead acid
-
transformer required : 16.5VAC, 40VA
-
2 system partitions… 2 account numbers
| - |
each partition
acts as a separate alarm system with any number of zones,
user codes, keypads and individually programmable features |
38 - 4 or 6 digit access codes
| - |
32 user codes, 1
system master code, 2 partition master codes, 2 duress
codes, and 1 maintenance code |
automatic arming by partition
| - |
each partition
may be programmed to auto-arm at its own time each day |
keypad lockout
| - |
panel can be
programmed to lockout keypad if a series of incorrect access
code entries are made |
'quick arm' and 'quick exit'
| - |
allows users to
arm and exit easily |
'stay/away' zones and 'stay' arming
| - |
security of
perimeter arming while premise is occupied |
door chime
| - |
programmable by
zone |
| - |
monitor a door by
having keypad beep when the door is opened and again when
door is closed |
128 event buffer
| - |
all events
automatically stored with time and date stamp to buffer |
| - |
events can be
printed on-site using the PC5400 serial printer interface
module, viewed through an LCD Keypad, or viewed and printed
via PC using DLS software |
Full Supervision
: The system continuously monitors the following trouble conditions :
AC power failure
trouble by zone
fire trouble
telephone line trouble
low battery
bell output trouble
loss of internal clock
tamper by zone
fail to communicate
aux power supply fault
module fault (supervisory or tamper)
camera troubles (on PC5015 with Downlook)
False Alarm Prevention Features
audible exit delay
audible exit fault
quick exit
urgency on entry delay
swinger shutdown
cross zone alarm
recent closing transmission
burglary verified timer *
double hit timer *
communication delay
rotating keypress buffer
arm/disarm bell squawk
* on PC5015 v2.2x and higher
Advanced Communications
supports all major formats including SIA and Contact ID
LINKS1000™ cellular communication
LINKS2150™ and LINKS2450™ long range radio communication
DVACS communication using PC5400 or PC5720 modules
Downlook video transmission using PC5108L module on Power832 PC5015
main control panel
event initiated personal paging
3 phone numbers (3rd backs up primary number)
2 account numbers
Integrated Intercom Audio
supports Central Station Two Way Voice and Home Intercom features
using PC5928 audio interface module, PC5921 intercom stations, and
PC5904 two way listen-in stations
Integrated CCTV
supports Downlook still frame video transmission using PC5108L
module on Power832 PC5015 main control panel
provides local VCR/monitor video switching for 8 cameras
Integrated Voice Assisted
Security & Home Automation
Escort5580 & 5580TC provide voice assisted security and
automation control for up to 32 X-10 devices plus thermostat
control on 5580TC
POWER
864 A NEW GENERATION
(PC-5020)
TECHNICALSPECIFICATIONS


Pictures PCB Boards DIAGRAM

|
|