ALARMSBC LOGO---back to home page

DSC NEW POWER SERIES
MODULES


MESSAGE
BOARD


FREE USER
MANUALS

English
International
Chinese


ALARM
COMPANIES

Canada
USA
UK
Australia
New Zeeland


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

-Wireless Devices 
-Central  Station
Equipment

-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector 
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren  

Promotion
Special Orders
&
ON SALE

Items


POINTS
of
INTEREST
 

-Metric Imperial US Conversion
-Frequently Asked Question
-Security Licence
-Statistics
-Standards
-How  Devices Works
-Tips to Improve Security
-Y2K


FALSE ALARMS

-False Alarms Fees
-British Columbia
-California
-Other US Cities


CENTRAL STATION


INSTALLATION
&
SERVICE


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


FREE  LINK
TO
 AlarmsBC


JOKES


DAILY NEWS


CANADA
MAP

 


BRITISH
COLUMBIA
MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


Our Guestbook


CONTACT US

 

 


CONTROL PANEL KEYPADS  - MODULES


Pictures PCB Boards

 

 

PC5100  

  • Video Verification Module VVM110

  • Data interface module PC-5401 

  • Status module PC-5601

 


8 Zone Expansion Module PC-5108

Adds 8 hardwired zones to the alarm system.

 

Adds 8 hardwired general purpose burglary or fire zones provides 125mA @ 12VDC auxiliary current, PTC protected
Connect up to 1000' (305m) from control panel via KEYBUS module current draw : 35mA @ 12VDC

 


Output Current Modules
PC-5208     PC5204    PC5200

PC5208
8 Output Low-Current Module
 
 

Adds 8 programmable outputs to the alarm system.  Each output is rated at 50mA.  Can be programmed to respond to one of 14 different system conditions .  Ideal for interfacing to home automation controller (Stargate, Time Commander Plus, or HomeVision) or directly to X10 PowerFlash Module.


PC5204ulc
Four Output High Current Module

  Provides 1 Amp of additional current (at 12VDC) for the alarm system and components.  Also adds 4 high current programmable outputs for door strikes, bells, and more. Requires it's own 16VAC 40VA transformer , backup battery , and enclosure 

 


PC5200
Power supply modules
 

 

Provides up to 1 Amp @ 12 VDC
Fully supervised for AC failure, low battery and AUX failure
Compatible with Power864 control panels

 


UParrow.gif (1001 bytes)


 PC-5400ULC Printer Module   

PC-5400DV DVAC


 

 

Allows the alarm system to print reports to a serial printer.  Prints 40 or 80 column on printers with baud rates of 300, 1200, 2400, or 4800.  Prints: zone, time, date & event type as they occur.

  • both PC5400 and PC5400DV may be used at the same time on a system
  • provides ULC Level 3 Line Security.
  • provides full DVACS reporting of all system events.
  • module is pre-programmed to SIA zone definitions
  • events simultaneously communicated via DVACS and other installed communications mode such as digital or cellular
  • full cross supervision between the system control panel and the DVACS module e.g problems with one will be communicated to the central station by the other.
  • central station requires Sur-Gard receiver with DVL2A version 2 or higher software.
  • complete with 8 pin jack, and communications and power cables for connection to F1/F2 subset.
  • connect up to 1000' (305m) from control panel via KEYBUS
  • module current draw : 65mA @ 12VDC
  • Compatible with all PowerSeries control panels

UParrow.gif (1001 bytes)


Escort Voice Assisted Telephone Control: 

PC5580TC   ESCORT MODULE WITH  BUILT IN THERMOSTAT INTERFACE and WITH  BUILT IN INTERFACE FOR X-10

The Escort telephone access module can turn any touch-tone telephone, any- where in the world, into a Power  system keypad with clear voice prompting and full customer control of their integrated  security system. The system's voice prompt gives plain language prompts in English, French, or Spanish, directing you through the system. Remote telephone access is available from your car, your office, or even your vacation spot.
 
Built in X-10 interfaces: . Transmit 32 X-10 commands. Global/Partition Control 16 schedules, 8 modes. Customized Commands, Access codes.
Module contains extensive library of voice prompts ie this
unit talks back to you. Program up to 6 words per label, 180 pre-
programmed system words, 241 pre-programmed library words.
T
hermostat control supports also up to four EMS-100 thermostats.
Not compatible with PC1555

escort pc board

escort.jpg (2363 bytes)

 

UParrow.gif (1001 bytes)


Fire Module PC5700 DUAL Telephone Line Monitoring

The PC5700 module is both a dual-line dialer module and an 8-zone hardwire expander module that can be used with the power series control panels. The module is typically used for fire applications and is only available in Canada. The module provides 4 general-purpose zones, 2 Class A supervisory water flow zones, a ground fault detection zone and a telephone line trouble zone.

 

 

UParrow.gif (1001 bytes)


PC5900  Audio Verification Module
 
Talk/Listen-in audio verification module
Up to four audio stations, four microphones (PC5921) and two speakers (PC5904), can be connected
Remotely controlled via touchtone phone
Compatible with Power series control panels 
All programming can be performed at the system keypad or remotely using DLS2002 software
Low current draw on main system (100mA)
500ft (152 m) maximum speaker range
1,000ft (305m) maximum microphone range

pc5900 audio board

 


PC5921 Two-way audio verification station

Interior Intercom Station
   

Two-way intercom, background music and room monitoring.  Each station can be used to initiate or receive pages, answer incoming calls, answer the doorbell, monitor rooms or sound an alarm follower.  An audio interface module installed with the main controller is required.  Each station must be home-run to the interface module using shielded 22 gauge, 4-conductor wire.

 

UParrow.gif (1001 bytes)

 

  
Copyright 1997 - 2010

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 04-Jan-2010
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 *  etc...  etc....

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US