3 DSC New Control Panel
PC-1616
PC-1832 PC-1864
New power
series control panels are backward compatible with all of the
previous power seris generation modules and keypads. They feature
a new board design with new firmware and over 100 new program
features
| |
PC580
|
PC1555MX
|
PC5010
|
PC5020
|
PC1616
|
PC1832
|
PC1864
|
|
On-Board Zones
|
4
|
6
|
8
|
8
|
6
|
8
|
8
|
|
Hardwired Zones
|
8
|
8
|
32
|
64
|
16
|
32
|
64
|
|
Wireless Zones
|
32
|
32
|
32
|
32
|
16
|
32
|
32
|
|
Keypad Zone Support
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
On-Board PGM
|
2
|
2
|
2
|
4
|
2
|
2
|
4
|
|
Keypads Supported
|
8
|
8
|
8
|
8
|
8
|
8
|
8
|
|
Partitions
|
1
|
1
|
2
|
8
|
2
|
4
|
8
|
|
User Codes
|
32 +Master Codes
|
32 +Master Codes
|
32 +Master Codes
|
32 +Master Codes
|
32 +Master Codes
|
32 +Master Codes
|
32 +Master Codes
|
|
AUX Current
|
500mA
|
500mA
|
500mA
|
500mA
|
700mA
|
700mA
|
700mA
|
DSC PC-1616
It features 6 hardwire zone inputs and can be expanded up to a
total of 16 hardwired zones and up to 16 wireless zones. Supports
up to 8 keypads and has two partitions.
|
Advanced Communications
Supports all major formats including SIA and
Contact ID
Skyroute™ and GSM3055i and 3060™, cellular communication
Event initiated personal paging
3 phone numbers (3rd backs up primary number)
2 account numbers
Local PCLINK™ and remote
upload/download capability
Program system using DLS software (version 6.5 or newer) via
direct PCLINK connection to control panel or remotely via modem
View status and trouble conditions, and system 128 event buffer
Remote access can be controlled by owner to prevent unauthorized
access to system
User call-up feature
Full
Supervision
The system continuously monitors the following trouble conditions:
AC power failure
Fire trouble
Trouble by zone
Telephone line trouble
Bell output trouble
Tamper by zone
Low battery
Loss of internal clock
Fail to communicate
Aux power supply fault
Module fault (supervisory or tamper)
System Operation
• 38 - 4 or 6 digit access codes
- 32 user codes, 1 system master code, 2 partition master codes,2
duress codes, and 1 maintenance code
• Keypad lockout
- panel can be programmed to lockout keypad if a series of incorrect
access code entries are made
• ‘Quick Arm’ and ‘Quick Exit’
- allows users to arm and exit easily
• ‘Stay/Away’ zones and ‘Stay’ arming
- security of perimeter arming while premise is occupied
• Door chime
- programmable by zone
- monitor a door by having keypad beep when the door is opened and
again when door is closed
• 128 event buffer
- all events automatically stored with time and date stamp to buffer
- events can be printed on-site using the PC5400 serial printer
interface module, viewed through an LCD Keypad, or viewed and
printed via PC using DLS software
|
False Alarm
Prevention Features
Audible exit delay
Audible exit fault
Urgency on entry delay
‘Quick Exit’
Swinger shutdown
Cross zone alarm
Communication delay
Arm/Disarm bell squawk
Recent closing transmission
Rotating keypress buffer
Integrated Voice Assisted
Security & Automation
ESCORT5580TC Voice Assisted Security & Automation Control
Module
• Turns any touch-tone phone into a fully
functional keypad with Global and Partition control
• Built-in power line interface for control of 32 X-10 automation
control devices
16 schedules with On Time, Off Time, and Day of
Week
8 user controlled automation modes
Full range of dimming levels for lighting control
Event activated control for any PGM output supported by the main
panel
• An extensive library of voice prompts for
security and automation operation, programming, and system status
feedback
250 system words for pre-programmed system
functions
240 word library for user programmable voice prompts for
Automation Item Labels, Automation Mode Labels, Partition Labels,
and Zone Labels
• Program up to 6 words per voice label
• Powerful ‘say number’ command can announce numbers from 0-999 in
three different ways
• Supports up to four EMS-100 thermostats
• EMS-100 has 4 temperature control modes :
day occupancy mode
night occupancy mode
auxiliary occupancy mode
away occupancy mode
• Each thermostat optionally supports:
up to six EMS-IDS remote indoor temperature
sensors for interior temperature averaging
one EMS-ODS outdoor temperature sensor for display of outdoor
temperature
• Connect up to 1000' (305m) from control panel
via KEYBUS
• Specifications
- Current draw: 150mA @ 12VDC
|
| |
|

DSC PC-1832
It features 8 hardwire zone inputs out of the box and
can be expanded up to a total of 32 hardwired or wireless zones.
Supports up to 8 keypads and has four partitions.
|
Full Supervision :
The system continuously monitors the following trouble conditions :
AC power failure
trouble by zone
fire trouble
telephone line trouble
low battery
bell output trouble
loss of internal clock
tamper by zone
fail to communicate
aux power supply fault
module fault (supervisory or tamper)
Integrated Voice Assisted
Security & Home Automation
Escort5580 & 5580TC provide voice assisted
security and automation control for up to 32 X-10 devices plus
thermostat control on 5580TC
|
False Alarm Prevention
Features
audible exit delay
audible exit fault
quick exit
urgency on entry delay
swinger shutdown
cross zone alarm
recent closing transmission
burglary verified timer *
double hit timer *
communication delay
rotating keypress buffer
arm/disarm bell squawk
Integrated Voice Assisted
Security & Home Automation
Escort5580 & 5580TC provide voice assisted
security and automation control for up to 32 X-10 devices plus
thermostat control on 5580TC
|
| |
|

DSC PC-1864
It features 8 hardwire zone inputs out of the box and
can be expanded up to a total of 64 hardwired zones and up to 32
wireless zones. Supports up to 8 keypads and has eight partitions.

|
AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES
=CENTRAL STATIONS
PROTOCOLS
=SOFTWARE
=INSTALLATION
TIPS
and
NOTES
=FORMS
=PRODUCTS
OVERVIEW
=TECH
SUPPORT PHONE NUMBERS
WEB HOSTING
=DATA
CENTER and
CONNECTIVITY
=VIRTUAL PACKAGES
DETAILS
=VIRTUAL
PACKAGES PRICES
=WEB CONTROL PANEL
=POLICIES
LINKS TO
RELATED SITES
JOKES
DAILY NEWS
CANADA MAP
GLOSSARY
SEARCHING
WWW
UNIVERSAL CURRENCY CONVERTER
CONTACT US
|