MESSAGE
BOARD
FREE
USER
MANUALS
English
International
Chinese
ALARM
COMPANIES
Canada
USA
UK
Australia
New Zeeland
ALARM
EQUIPMENT
DSC
ADEMCO
PARADOX
FBI
-Wireless
Devices
-Central
Station
Equipment
-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren
Promotion
Special Orders
&
ON SALE
Items
POINTS
of
INTEREST
-Metric Imperial
US
Conversion
-Frequently
Asked Question
-Security Licence
-Statistics
-Standards
-How Devices
Works
-Tips to Improve Security
-Y2K
FALSE
ALARMS
-False Alarms Fees
-British Columbia
-California
-Other US Cities
CENTRAL STATION
INSTALLATION
&
SERVICE

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES
=CENTRAL STATIONS
PROTOCOLS
=SOFTWARE
=INSTALLATION
TIPS
and
NOTES
=FORMS
=PRODUCTS
OVERVIEW
=TECH
SUPPORT PHONE NUMBERS
WEB HOSTING
=DATA
CENTER and
CONNECTIVITY
=VIRTUAL PACKAGES
DETAILS
=VIRTUAL
PACKAGES PRICES
=WEB CONTROL PANEL
=POLICIES
LINKS TO
RELATED SITES
FREE LINK
TO
AlarmsBC
JOKES
DAILY NEWS
CANADA
MAP
BRITISH
COLUMBIA
MAP
GLOSSARY
SEARCHING
WWW
UNIVERSAL CURRENCY CONVERTER


CONTACT US
|
Power &
Communications
via
Two-Wire Addressable Multiplex Loop
For use with:
Power832 - Power864 - MaxSys
PC-5100 Addressable Multiplex Loop (AML) interface module
AMX-400 Addressable Loop (AML) Regenerator
Module
AMA-100
Glassbreak Detector
AMB-300 PIR Motion Detector
AMB-500 Ceiling Mount, 360° PIR Motion Detector
AMB-600 Pet-Resistant PIR Motion Detector
AMP-700 Door/Window Contact
AMS-220 Photoelectric Smoke Detector
DISCONTINUED
AMS-220T Photoelectric Smoke Detector with 135° Heat Detector
DISCONTINUED
FSB-210BT Photoelectric Smoke Detector with 135° Heat Detector
(REPLACE AMS-220 AND 220T)
|

|
PC5100
Addressable Loop Interface
Module (PowerSeries)
ADDRESSABLE MULTIPLEX LOOP
Digital
Security Controls (DSC) has introduced the PC5100 Addressable
Multiplex Loop (AML) interface module. The PC5100 provides for
the connection of up to 32 two-wire addressable devices to DSC's
award winning Power832 security system.
The
PC5100 works seamlessly with the Power832 platform to provide
added wiring flexibility permitting such configurations as
"Daisy Chain", "T" tap and "Star".
Simple 2-wire hook-up reduces installation time while providing
system wide point I.D. of all AML devices.
The
PC5100 also is an excellent tool for retrofitting existing two
wire systems with the power and alarm communication on a single
pair of wires. Whether the installation requires smoke, motion,
pet-resistant or glassbreak detectors, DSC offers the following
full line of UL, ULC and CE approved Addressable devices .
|
|

|
AMX-400
Addressable Loop (AML) Regenerator
Module
Loop
Repeater/Isolator Module
- Can be
used to repeat and re-power the AML loop to allow for longer
wire runs:
- Requires 12 VDC power source
- Will
isolate the wire run in the event of a problem
|

|

|
AML-770 Addressable
Loop Isolator
Loop Isolator
Module
- Can be used
to isolate burglary detectors from fire detectors on the same wire
run
|
|

|
AMA-100
Glassbreak Detector
- Based on
the Acuity hardwire glassbreak detector
- Detects
all types of breaking glass
- Plate, laminated, safety and tempered
- Can be
tested using the AFT-100 Glassbreak Tester
- Built-in
tamper switch
| Electrical: |
Operating
voltage... |
9
to 14V RMS* |
Current
consumption:Standby...3,5mA
Alarm...3,5 mA
Test...3.5 mA
|
| Microphone
type... |
Omnidirectional
Electret |
| Mechanical: |
Dimensions
(L x W x H)... |
3.5
x 2.5 x 0.8 in
(89 x 64 x 20mm) |
|

|

|
AMB-300 PIR Motion Detector
| Operational: |
| Coverage
angle (wall to wall lens)... |
90°
minimum |
| Vertical
adjustment... |
from
+5 to -10° |
| Mounting
height... |
6' to
10' (2 to 3.5m) nominal 7.5' (2.3m) |
| Walk
duration speed... |
0.5
to 10 ft/s (0.15 to 3.0 m/s) |
| Alarm
duration... |
2
to 3 seconds |
| Environmental/
Immunity: |
| Operating
temperature... |
32
to 122° F (0 to 50° C) |
| Operating
humidity... |
5%
to 95% non-condensing |
| RF
immunity... |
50
V/m from 1 to 1,200MHz |
| Transient
immunity... |
2.4
kV @ 1.2 joules |
| Static
immunity... |
25
kV |
| White
light immunity... |
20,000
Lux at the detector |
| Electrical: |
| Operating
voltage... |
9
to 14 V RMS* |
| Standby
current... |
2.5
mA |
| Alarm
current... |
2.5
mA |
| Test
current... |
5.0
mA |
| Physical: |
| Dimensions... |
3.5"
H x 2.5"W x 1.87"D
(8.9 x 6.4 x 4.8) cm |
|

|

|
AMB-500 Ceiling Mount, 360° PIR Motion Detector
- Based on
the Bravo 5 hardwire motion detector
- Patented
MLSP (Multi-Level Signal Processing)
- Coverage
diameter based on mounting height
- Built-in
tamper switch
Environmental/Immunity :
Operating temperature . . . . . . . . . . .32 to 120°F (0 to 49°C)
Operating humidity . . . . . . . . . . . . . .5% to 95%
non-condensing
RF/EMI immunity . . . . . . . . . . . . . . .50V/m from 0.01 to
1,200MHz
Transient immunity . . . . . . . . . . . . . .2.4kV @ 1.2 joules
Static immunity . . . . . . . . . . . . . . . .25kV
Electrical :
Operating voltage . . . . . . . . . . . . . . .9 to 14VRMS*
Standby current . . . . . . . . . . . . . . . .0.75mA
Alarm current . . . . . . . . . . . . . . . . . .0.9mA
Test current . . . . . . . . . . . . . . . . . . .3mA
Tamper switch contact rating . . . . . .0.1A @ 24VDC
Physical :
Dimensions . . . . . . . . . . . . . . . . . . .4.6"Ø x 1.4"D (11.7
x 3.6cm)
* compatible with DSC AML (Addressable Multiplex
Loop) voltage
Mounting height above floor Coverage diameter
8' (2.4m).................................... 24' (7.3m)
10' (3.0m).................................. 30' (9.2m)
12' (3.6m).................................. 40' (12.2m)
|
|

|
AMB-600 Pet-Resistant PIR Motion Detector
| Operational: |
| Mounting
height... |
6'
to 10' (2 to 3 m) |
Lens
horizontal
pattern angle... |
100°
maximum |
| Vertical
adjustment... |
from
+5 to -10° |
| Alarm
duration... |
2
to 3 seconds |
| Walk
speed... |
0.5
to 10 ft/s (0.15 to 3.0 m/s) |
| Environmental/
Immunity: |
| Operating
temperature... |
32
to 122° F(0 to 50° C) |
| Operating
humidity... |
5%
to 95% non-condensing |
| RF
immunity... |
10
V/m 80% A.M., from 80 to 1,000MHz |
| Transient
immunity... |
2.4
kV at 1.2 joules |
| Static
immunity... |
15
kV |
| White
light immunity... |
4
kLux |
| Electrical: |
| Operating
voltage... |
9
to 14 V RMS* |
| Standby
current... |
3.5
mA |
| Alarm
current... |
3.5
mA |
| Test
current... |
6.5
mA |
| Physical: |
| Dimensions... |
4.9"H
x 2.76"W x 1.75"D (12.5 x 7.0 x 4.5 cm) |
| Mounting... |
wall,
corner, or ceiling |
|

|

|
AMP-700 Door/Window Contact
- AMP-700
door/window contact with built-in reed switch
- AMP-701
door/window contact with normally closed input
- AMP-702
fire point module with normally open, EOL resistor supervised
input
- AMP-704
four door/window contacts with normally closed, single or double
EOL inputs
- AMP-704F
for fire inputs
|

|

|
AMS-220 Photoelectric Smoke Detector
Operating voltage.....9 to 14
VRMS*
|
Current
consumption.....
|
Standby
|
Alarm
|
Test
|
|
AMS-220.....
|
0.8mA
|
1.5mA
|
1.5mA
|
|
AMS-220T.....
|
0.8mA
|
1.5mA
|
1.5mA
|
Smoke sensitivity .....2.0%/ ft (305 mm) obscuration
±0.6%/ ft (305 mm) (UL) 2.5%/ ft (305 mm) obscuration ±0.5%/ ft (305 mm)
(ULC)
Operating environment .....32 to 122°F (0 to 50 °C)
5% to 95 % RH, non-condensing
Dimensions .....5.6"Ø x 2"D (14.2
x 5.1cm)
Field test .....Software programmable test
options and/or Gemini 501
Smoke Alarm Analyzer
|

|

|
AMS-220T Photoelectric Smoke Detector with 135° Heat Detector
Operating voltage.....9 to 14
VRMS*
|
Current
consumption.....
|
Standby
|
Alarm
|
Test
|
|
AMS-220.....
|
0.8mA
|
1.5mA
|
1.5mA
|
|
AMS-220T.....
|
0.8mA
|
1.5mA
|
1.5mA
|
Temp sensor .....135°F (57°C) fixed
Smoke sensitivity .....2.0%/ ft (305 mm) obscuration
±0.6%/ ft (305 mm) (UL)
2.5%/ ft (305 mm) obscuration ±0.5%/ ft (305 mm) (ULC)
Operating environment .....32 to 122°F (0 to 50 °C)
5% to 95 % RH, non-condensing
Dimensions .....5.6"Ø x 2"D (14.2
x 5.1cm)
Field test .....Software programmable test
options and/or Gemini 501
Smoke Alarm Analyzer
|

|

|
FSB-210BT
REPLACE AMS-220T
Photoelectric
Smoke Detectors
- Automatic drift
compensation
- High/Low sensitivity
trouble
- Easy-maintenance
replaceable chamber
- Local test button (units
with horn)
- Magnet activated test
(units without horn)
- Optional built-in 85 dB
horn
- Unique, non-contact
sensitivity reading with hand-held FSD-100 test meter
- Built-in,
fixed-temperature heat sensor option with an alarm
threshold of 135°F (57.2°C)
- UL268 Listed for