ALARMSBC LOGO---back to home page

EQUIPMENT  DSC


MESSAGE
BOARD


FREE USER
MANUALS

English
International
Chinese


ALARM
COMPANIES

Canada
USA
UK
Australia
New Zeeland


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

-Wireless Devices 
-Central  Station
Equipment

-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector 
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren  

Promotion
Special Orders
&
ON SALE

Items


POINTS
of
INTEREST
 

-Metric Imperial US Conversion
-Frequently Asked Question
-Security Licence
-Statistics
-Standards
-How  Devices Works
-Tips to Improve Security
-Y2K


FALSE ALARMS

-False Alarms Fees
-British Columbia
-California
-Other US Cities


CENTRAL STATION


INSTALLATION
&
SERVICE


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


FREE  LINK
TO
 AlarmsBC


JOKES


DAILY NEWS


CANADA
MAP

 


BRITISH
COLUMBIA
MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


Our Guestbook


CONTACT US

 

 

 

   

MAXSYS 4010

 ( DISCONTINUED )

dsc4010.JPG (16802 bytes)

8-64 ZONE MODULAR NETWORK SECURITY SYSTEM

  • UP TO 64 FULLY PROGRAMMABLE ZONES
    - 8 ZONES ON MAIN CONTROL PANEL
    - HARDWIRE AND WIRELESS ZONE EXPANSION
    - ALL ZONES PROGRAMMABLE AS BURGLARY OR FIRE
    - ASSIGN ZONES TO ONE OR MULTIPLE PARTITIONS
    - 18 PROGRAMMABLE ZONE TYPE

  • 4 PARTITIONS
    - ALL FEATURES PROGRAMMABLE BY PARTITION
    - SEPARATE SIREN OUTPUT PROGRAMMABLE FOR EACH PARTITION
    - 128 - 4 OR 6 ACCESS CODES ASSIGNABLE TO ONE OR SEVERAL PARTITIONS

  • 600 EVENT BUFFER
    - EVENT BUFFER CAN BE : PRINTED ON SITE OR VIEWED FROM KEYPAD OR DLS SOFTWARE

  • ALARM OUTPUT
    - BELL OUTPUT - 700 mA @ 12VDC
    - ADDITIONAL SIREN OUTPUT HIGH CURRENT USING PC-4204 (4 OUTPUT PER MODULE) MAX. 12 MODULES PER SYSTEM
    - ADDITIONAL 144 LOW CURRENT OUTPUT WITH PC-4216

UParrow.gif (1001 bytes)


MAXSYS 4020


dsc4020.JPG (16802 bytes)



16-128 ZONE MODULAR NETWORK SECURITY SYSTEM

  • UP TO 128 FULLY PROGRAMMABLE ZONES
    - 16 ZONES ON MAIN CONTROL PANEL (zones can be NC with no EOLR, NO/NC with single EOLR or NC with double EOLR.
    - HARDWIRE AND WIRELESS ZONE EXPANSION
    - ALL ZONES PROGRAMMABLE AS BURGLARY OR FIRE
    - ASSIGN ZONES TO ONE OR MULTIPLE PARTITIONS
    - 30 PROGRAMMABLE ZONE TYPE

  • 8 PARTITIONS  ( 9 accounts)
    - ALL FEATURES PROGRAMMABLE BY PARTITION
    - SEPARATE SIREN OUTPUT PROGRAMMABLE FOR EACH PARTITION
    - 128 - 4 OR 6 ACCESS CODES ASSIGNABLE TO ONE OR SEVERAL PARTITIONS

  • 3000 EVENT BUFFER
    -  3000 EVENT BUFFER CAN BE : PRINTED ON SITE OR DLS SOFTWARE
    -  2800 VIEWED FROM KEYPAD 

  • ALARM OUTPUT
    - BELL OUTPUT - 700 mA @ 12VDC
    - ADDITIONAL SIREN OUTPUT HIGH CURRENT USING PC-4204 (4 OUTPUT PER MODULE) MAX. 16 MODULES PER SYSTEM
    - ADDITIONAL 144 LOW CURRENT OUTPUT WITH PC-4216

  • SUPERVISED DIGITAL ALARM COMMUNICATOR with 4 formats :
    - 20bps, 1400/ 2300Hz handshake
    - Contact ID
    - SIA with auto-reporting codes

  • MULTIPLE COMMUNICATION CAPABILITIES
    -
    Built in digital dialer
    -optional module for DVAC
    -Optional Cellular Communication

  • COMPREHENSIVE  SCHEDULING
    -
    99 date schedules
    -50 arm/disarm schedules
    -16 automation schedules
    -4 two year holiday schedules
    -99 open/close suppression schedules
    -50 addressable smoke detector test schedules

UParrow.gif (1001 bytes)


KEYPADS

 LCD-4500     LCD-4501


LCD-4501 
 

  • up to 16 keypads

  • any mix of LCD4500/ 4501 keypads can be used in a system

  • keypads can be assigned as "global" – for system wide control or "partition" – for operation of a specific partition only

 

  • two line, 32 character LCD display

  • programmable LCD display contrast and brightness

  • LCD display and keys backlit for low light viewing

  • 'backlighting boost'provides extra key back-lighting when any key is pressed

  • individual LED indicators for Trouble, Armed, and Ready

  • piezo buzzer provides audible feedback for correct/ incorrect key entries, entry/ exit alert, and system trouble conditions

  • three dedicated keys for keypad activated alarms :Fire, Panic, Auxiliary

 

  • keypad activated Duress code… user code programmed as a Duress code.

  • 5 individual programmable function keys…see Function Key Options for a complete list of available functions.

 

 
LCD4501 Keypad…factory default functions are :
1. Stay...Stay arming
2. Away.. Away arming
3. Chime... Door chime on/off
4. Reset...Reset smoke detectors
5. Exit...Activate quick exit

 


UParrow.gif (1001 bytes)

LCD-4500 
( DISCONTINUED )

LCD-4500 Series… without dedicated function keys

LCD4500...

LCD keypad

LCD4500T...

LCD keypad with wall tamper

LCD4520...

LCD keypad with red bezel for fire panels

LCD4520T...

LCD keypad with red bezel and wall tamper

Canadian Version

LCD4500R...

LCD keypad with red bezel for fire panels (CND)

LCD4500TR...

LCD keypad with red bezel and wall tamper (CND)

  • two line, 32 character LCD display
  • programmable LCD display contrast and brightness
  • LCD display and keys backlit for low light viewing
  • individual LED indicators for Trouble and Armed
  • piezo buzzer provides audible feedback for correct/ incorrect key entries, entry/ exit alert, and system trouble conditions
  • three dedicated keys for keypad activated alarms :
    - Fire, Panic, Auxiliary
  • keypad activated Duress code… user code programmed as a Duress code.

UParrow.gif (1001 bytes)


MAXSYS MODULES

A complete line of modules are available for the MAXSYS system including zone expanders, output modules, power supplies and access control modules. All modules utilize the 4-wire communication bus (COMBUS), saving time and money by reducing the number of wire runs needed.


MAXSYS PC4164 - 433Mhz RF Receiver
 

pc-4164 module by dsc

Now up to eight PC4164 receivers can be enrolled on the MAXSYS PC4020 v3.2 control panel, increasing security and extending coverage of wireless zones.
 
  The PC4164 receives signals from DSC wireless devices such as universal transmitters (WLS925), glassbreak detectors (WLS912), and PIR motion detectors (WLS904, WLS904P).

 


 MAXSYS PC4401 Serial Interface/Printer Module

pc 4401pc 4400

  • Connect up to 4 modules
  • Each module can perform 1 of the following functions:
    - Serial printer
    - PC-Link isolation
    - DVACS (Canada only)
    - DataLink bi-directional RS232

 

  This multi-use module acts as a printer interface and as a Datalink® 2-way serial data port.
The printer interface will allow for the printing of time and date-stamped system reports, and supports 300, 1200, 2400, and 4800 bps serial printers.
 

 

The Datalink port supports 2-way RS-232 communication for use by system integrators.Use as a true RS-232 serial interface to a serial printer and receive comprehensive management information reports from MAXSYS' 3,000 event buffer or, in Canada, optionally use the PC4401 as a DVACS interface to take advantage of available high security DVACS communications networks.

UParrow.gif (1001 bytes)


MAXSYS Audio Interface Modules PC4936 and PC4937

The PC4936 and PC4937 audio modules support a variety of features on the PC4020 v3.2 control panel, including a 15-station intercom, 2-way voice communication, call waiting, intercom, monitoring, verbal door chime, doorbell function, internal sounder, telephone answering, 'do not disturb' mode, doorstrike activation, music input, voice alarm annunciation, and audio user help.
   

UParrow.gif (1001 bytes)

MAXSYS Expansion Modules.  PC4108  8 Zones   PC4116 16 zones 
up to 128 hardwired zones

 

zones can be NC with no EOLR, NO/NC with single EOLR or NC with double EOLR (5600ohm resistors)
30 programmable zone types & 8 zone options
connect up to 1,000' (305m) from control panel via COMBUS

 


MAXSYS Expansion  quad relay/ power supply modules PC4204  

 


The PC4204 is a dual purpose power supply/ output module, providing programmable relay outputs for controlling external devices and power to repower the Combus… to provide additional power as required for downstream devices which are powered off of the Combus
.  64 relay outputs… using PC4204 quad relay/ power supply modules – up to 16 modules/system – the PC4204 also provides up to 16 amps of auxiliary power and can be used to repower the Combus.

UParrow.gif (1001 bytes)


MAXSYS Expansion  point/ graphic annunciation… using PC4632/PC4664

 

provides point/ graphical display of system conditions :
- zone alarms
- partition status (armed, ready, trouble)
- common fire zone trouble
- common bell trouble
- common battery trouble
- common system trouble

  • uses PC4216 modules to power plug-in LED indicator lights
  • customize display using using transparency overlays and plug-in LED's
  • continuous hinged, screw closure front panel
  • surface or flush mounted with optional trim
  • current draw…15mA per PC4216 plus 20mA per active LED (from Combus)

 

 

PC4632 – 32 Point Capacity

  • 8.5" x 11" (21.6 x 27.9cm) display area complete with :

    one....PC4216, 16 point low-power output module
    one...PC4600LG pkg. of 4 LED grids to cover entire display area
    one..PC4600LA-M pkg. of 1 green, 10 red, and 5 yellow LED assemblies
    one...PC4632GP point/ graphic display package which includes a preprinted point display overlay for 32 indicators and space for labels

  • capacity for twoPC4216 modules for 32 indicators
  •  

    PC4664 – 64 Point Capacity

  • 11" x 17" (27.9 x 43.2m) display area complete with :

    two....PC4216, 16 point low-power output modules
    two...PC4600LG pkgs. of 4 LED grids to cover entire display area
    one...PC4600LA-M pkg. of 1 green, 10 red, and 5 yellow LED assemblies
    one...PC4600LA-R pkg. of 16 red LED assemblies
    one...PC4632GP point/ graphic display package which includes: preprinted point display overlay for 64 indicators and space for labels

  • capacity for two PC4216 modules for 32 indicators
  •  

     

    UParrow.gif (1001 bytes)


    MAXSYS Expansion  32 access-controlled doors… using up to 16 PC4820 
    two reader access control modules with standalone capability.

     

    • 2 reader access control - 2 single reader doors or 1 door with entry/ exit readers

    • flexible card holder privileges
      - assign individual access privileges by door & by schedule
      - define user rights to permit arming & disarming by partition
      - designate "privileged" users who are authorized to validate access for "wait for privileged" users (guardian function)

     

     
    • full stand-alone operation… complete card database & all programming is maintained in the PC4820's non-volatile memory

    • 64 access levels
    • 99 seven-day schedules
      - 4 time intervals per schedule
    • 4 two year holiday groups - 730 holidays
    • individual door-unlock schedules
    • automatic switching between daylight savings & standard time
    • program via keypad, or via computer with DLS-2 downloading software
    • non-volatile RAM -> does not lose programming when powered down

    UParrow.gif (1001 bytes)


    MAXSYS Expansion Escort PC4580

     

    The Escort4580(1) allows the telephone to be used as a keypad while providing the user with plain language operational and programming voice prompts, and system status reports. In addition, X-10 automation using the Escort4580 module – controls up to thirty two X-10 devices and provides voice-assisted system status and control from any touchtone telephone. Escort acts as an interface to X-10 automation control devices and provides voice-assisted operation and programming of these devices. System Status & Control - Voice Prompt Assisted.

    UParrow.gif (1001 bytes)


    UParrow.gif (1001 bytes)

     


      
    © Copyright 1997- 2010

    Information in this document is subject to change without notice.
    Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
    UPDATE 04-Jan-2010
    MMC&S Inc.


    MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

    ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
     motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
     Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

    INSTALLATION / SERVICE / MONITORING

    POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
     how the sensor works  *  y2k * basic security systems 101 *  etc...  etc....

    FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

    LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

    WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

    JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

     ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
     ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
    etc...  etc....

    CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


    CONTACT US