AlarmsBC presents alarm companies BC Canada US Australia UK,alarm and security equipment, free user manuals, installation manuals, installer and tech help, false alarms fees and permits, alarm technicians security help tips, fre reciprocal links, points of interest, Jokes and funny pictures

ADEMCO EQUIPMENT


MESSAGE
BOARD


FREE USER
MANUALS

English
International
Chinese


ALARM
COMPANIES

Canada
USA
UK
Australia
New Zeeland


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

-Wireless Devices 
-Central  Station
Equipment

-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector 
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren  

Promotion
Special Orders
&
ON SALE

Items


POINTS
of
INTEREST
 

-Metric Imperial US Conversion
-Frequently Asked Question
-Security Licence
-Statistics
-Standards
-How  Devices Works
-Tips to Improve Security
-Y2K


FALSE ALARMS

-False Alarms Fees
-British Columbia
-California
-Other US Cities


CENTRAL STATION


INSTALLATION
&
SERVICE


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


FREE  LINK
TO
 AlarmsBC


JOKES


DAILY NEWS


CANADA
MAP

 


BRITISH
COLUMBIA
MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


Our Guestbook


CONTACT US

 
 

RESIDENTIAL BURGLAR CONTROL PANELS


 

 vista 10, vista20, vista 40,4110 xmp, vista 50, vista 40

 

VISIT THE UPDATED PLUS SERIES OF RESIDENTIAL ALARM PANELS

RESIDENTIAL CONTROL PANEL CHART


 



Vista-10SE
DISCONTINUED

With six zones and 5800 wireless zone expansion, the VISTA-10SE is the industry’s most economical and sophisticated panel with light and appliance control.
vista 10  With six zones and 5800 wireless zone expansion, the VISTA-10SE is the industry’s most economical and sophisticated panel with light and appliance control.

Dependable features to meet your most demanding installations:

  • Six hardwired zones standard
  • Expands to 22 total zones when using 5800 wireless
  • Seven user codes
  • Two-method downloading
  • Supports up to four relays
  • False alarm prevention features
  • Fast and easy E2 programming mode
  • Wireless Receiver Systems

    • 5800 receivers
      — 5881ENL up to 8 zones - 60mA
      — 5881ENM up to 16 zones - 60mA
    • All receivers support
      — Diversity reception with two antennae
      — Remote mounting for best location
      — Unique supervision and low battery indications by point
  • Transmitters

    • 5800 Series
      — Three-Volt Duracell lithium batteries
      — One mile range
      — Tamper is standard
  • Wireless Remote Control - 
    5804 Four-Button Wireless Key,  
    5804BDV Bi-Directional  Wireless Key with system status feedback or 
    5804WATCH Four-Button Wireless Key
    Single or Dual Button Wireless Personal Panic: 5802MN and 5802MN2
    Home Automation: Activates lights, appliances, garage doors, and numerous other devices

  • VISTA Interactive Phone Module (VIP): Gives the end user control of their system from any touchtone phone; the 4286 VIP Module responds in clear English, with over a 100 word vocabulary
  • Full English Display Keypads: Provides clear understanding of system status and zone locations
  • Paging: Openings, closings, alarm and trouble messages can be sent directly to a pager, allowing system status to be confirmed; parents can use this feature to verify that their children have arrived home
  • QUICK EXIT: Enables users to leave the house for a brief time without disarming the system
  • UL Residential Fire and Burglary and CFM


Vista-15
DISCONTINUED
 

  • Six hardwired zones
  • Expands to 32 total zones (up to 26 wireless and/or 14 hardwired zones)
  • 16 user codes
  • 48 event log with date/time stamp
  • Two-wire or four-wire smoke detectors
  • Fast and easy E2 programming mode

Security & False Alarm Reducing Enhancements: 

  • Exit delay reset
  • Alarm cancel verification
  • Unvacated “Auto-Stay”
  • Cross zoning/alarm verification
  • Short vs. open detection & reporting
  • Telephone-line monitor
  • Arming level increase

End User System Features: 

  • Easy-to-use single button operation
    • Arm Away • Arm Stay
    • Arm Night • Page
  • Quick exit
  • Quick arm
  • X-10 control & 4 relays supported for home management
  • Enhanced paging capabilities
  • 24-hour monitoring zone
  • Compatible keypad family

Interface Devices :

  • Wireless remote control
    – 5804 - Four button, fully programmable key
    – 5804BD - Four button, fully programmable key with status feedback for added security
    – 5827BD - Wireless keypad with status feedback
  • Phone Control
    – 4285 - Turns any touch-tone phone into a voice response keypad

Hardwired Expansion Devices :

  • 4219 - eight hardwired zones - 16mA
  • 4204 up to four relays - 15mA standby (each active relay draws an additional 40mA)
  • 4229 - eight hardwired zones and two relays - 36mA
  • Powerline Support
    — 4300 transformer/interface
  • Keypads
    — 6128 fixed English LCD - 85mA/40mA
    — 6139 custom English (required for programming) - 100mA
  • Voice module 4285 VIP - 160mA
  • Supports 16 two-wire smoke detectors
  • 5881L up to 8 zones - 50mA, 5881M up to 16 zones - 50mA, 5881H up to 26 zones - 50mA
  • Supports Eagle 1225 & 1221 boards
  • UL Residential Fire and Burglary and CFM


Vista-15P

  • Six hardwired zones
  • Expands to 32 total zones (up to 26 wireless and/or 14 hardwired zones)
  • 16 user codes
  • 48 event log with date/time stamp
  • Two-wire or four-wire smoke detectors
  • Fast and easy E2 programming mode

Security & False Alarm Reducing Enhancements : 

  • Exit delay reset
  • Alarm cancel verification
  • Unvacated “Auto-Stay”
  • Cross zoning/alarm verification
  • Short vs. open detection & reporting
  • Telephone-line monitor
  • Arming level increase

End User System Features :

  • Easy-to-use single button operation
    • Arm Away • Arm Stay
    • Arm Night • Page
  • Quick exit
  • Quick arm
  • X-10 control & 4 relays supported for home management
  • Enhanced paging capabilities
  • 24-hour monitoring zone
  • Compatible keypad family

Interface Devices : 

  • Wireless remote control
    – 5804 - Four button, fully programmable key
    – 5804BD - Four button, fully programmable key with status feedback for added security
    – 5827BD - Wireless keypad with status feedback
  • Phone Control
    – 4285 - Turns any touch-tone phone into a voice response keypad

Hardwired Expansion Devices : 

  • 4219 - eight hardwired zones - 16mA
  • 4204 up to four relays - 15mA standby (each active relay draws an additional 40mA)
  • 4229 - eight hardwired zones and two relays - 36mA
  • Powerline Support
    — 4300 transformer/interface
  • Keypads
    — 6128 fixed English LCD - 85mA/40mA
    — 6139 custom English (required for programming) - 100mA
  • Voice module 4285 VIP - 160mA
  • Supports 16 two-wire smoke detectors
  • 5881L up to 8 zones - 50mA, 5881M up to 16 zones - 50mA, 5881H up to 26 zones - 50mA
  • Supports Eagle 1225 & 1221 boards
  • UL Residential Fire and Burglary and CFM


Vista-20P
vista 20  5800 wireless zone expansion, the VISTA is the industry’s most economical and sophisticated panel

  • Eight on-board hardwire zones standard (15 when Zone Doubling feature is used)
  • Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
  • Wireless keys can be programmed without using zones
  • Sixteen output devices
    – Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or
    – X-10 devices (when used with a 4300 transformer)
  • Two low current on-board trigger outputs
  • 100 Event Log viewable at system keypads with time/date stamp
  • 48 system user codes assignable to either partition
  • Two independent partitions plus a common partition
    – Global Arming from any system keypad
    – Goto function to view or operate one partition from the other
    – Separate partition account numbers
  • Four installer configurable zone types allow  the installer to create custom zone types by assigning all zone attributes
  • Multiple actions on output devices depending on system "state"
    – Turns lights off  when system arms
    – Turns the same lights on when system disarms
    – Flashes same lights when system is in alarm
  • Built-in phone line cut monitor with programmable delay and annunciation options
    – Display on system keypads
    – Trigger local sounders
    – Trigger system bell
  • Supports four-wire, and up to 16, two-wire smokes
    – Works with Sentrol Clean Me™ maintenance signal

End-User Features :

  • Now viewable on system keypads:
    – Exit countdown
    – Time & date display*
    – Event log*
  • Auto keypad backlighting on entry
  • Keyswitch arming
  • Programmable macro buttons & single button arming
  • A variety of wireless remote controls for single button operation
  • User scheduling
    – Automatically activates X-10β and relays at a programmed times
    – Latchkey reports to pagers
    – Auto Arm/Disarm
    – "User Access" time windows
  • Supports up to four end user numeric pagers
  • VIP Module allows system control from any touchtone phone
  • Chime by zone
    *Requires custom alpha keypad

Expansion Devices

  • 4219 - Eight hardwired zones - 16mA
  • 4204 - Up to four relays - 15mA standby (each active relay draws an additional 40mA)
  • 4229 - Eight hardwired zones and two relays - 36mA

Accessories

  • 4286 VIP Voice Module - 220mA
  • 5881ENL RF Receiver supports up to 8 zones - 60mA,
    5881ENM supports up to 16 zones - 50mA,
    5881ENH supports up to 40 zones - 50mA
  • Supports Eagle 1225 & 1221 boards

Keypads :

  • 6160/6139 Custom English (required for programming)
    – 150mA/40mA (6160)
    – 130mA/40mA (6139)
  • 6150/6128 Fixed English LCD
    – 70mA/40mA (6150),
    – 40mA/20mA (6128)
  • 6150RF Fixed Engish LCD with built-in receiver
    – 105mA/80mA

Smoke Detectors

  • Supports up to 16 two-wire smoke detectors
  • Supports four-wire smoke detectors
  • UL Residential Fire and Burglary and CFM


Vista-20SE
DISCONTINUED
 

vista 20  5800 wireless zone expansion, the VISTA is the industry’s most economical and sophisticated panel

  • Eight hardwire zones standard
  • Expands to 38 total zones (30 zones using 5800 wireless and/or 16 hardwired zones)
  • 48 event log
  • Two partitions with common area logic, which is ideal for the entry doors in a mother/daughter residence or lobby of a small office building
  • Built-in phone line cut monitor
  • 15 user codes per partition
  • Supports four relays or eight X-10 devices
  • Fast and easy E2 programming mode

Convenience and control features of the Vista-20SE:

  • Wireless remote control - single button system control with a wireless device
    —5804 - four button programmable wireless key
    —5804BD - a bi-directional button programmable wireless key, with system status feedback
  • Home automation to activate lights, appliances, garage doors and numerous other devices
  • VIP phone module gives the end user control of the system from any touch tone phone
  • Quick exit enables users to leave the house for a brief time without disarming the system
  • Full English display keypads provide a clear understanding of system status and zone locations
  • Chime by zone can be activated when the system is disarmed; this feature programs entrance and exit points to chime when opened
  • Paging sends openings, closings, alarm and trouble messages directly to a pager, allowing system status to be confirmed; parents can use this feature to verify that their children arrived home
  • Ten custom alpha words
  • False alarm reduction features

Output Control

  • Supports one relay board (part no 4204) for four relays
  • Optional X-10 transformer/interface (part no. 4300) may be used to control up to eight X-10 receiving devices

Hardwired Expansion Devices

  • 4219 - eight hardwired zones - 16mA
  • 4204 - up to four relays - 15mA standby (each active relay draws an additional 40mA)
  • 4229 - eight hardwired zones and two relays - 36mA
  • Powerline Support - 4300 transformer/interface
  • Keypads
    - 6139 custom English (required for programming) - 100mA
    - 6128 fixed English LCD - 85mA/40mA
  • Voice module 4285 VIP - 160mA
  • Two wire smoke detectors
  • 5881L up to 8 zones - 50mA, 5881M up to 16 zones - 50mA, 5881 H up to 24 zones - 50mA
  • Supports Eagle 1225 & 1221 boards
  • UL Residential Fire and Burglary and CFM


Vista-30PSE
DISCONTINUED

vista 20  5800 wireless zone expansion, the VISTA is the industry’s most economical and sophisticated panel

  • 30 wireless zones, two hardwired zones standard
  • Supports eight additional hardwired zones (22 wireless zones remain)
  • Seven user codes
  • Compatible with ADEMCO's 5800 series of wireless remotes
  • Supports 4286 VIP Phone Module
  • Supports up to four relays
  • False alarm reduction features
  • Paging capabilities

Convenience and control features of the VIA-30PSE

  • Single-button control of system from wireless devices:
    – 5804 - Four-button programmable wireless key
    – 5804BD - Bidirectional button programmable wireless key with status features
  • Single or dual-button wireless personal panic:
    – 5802MN
    – 5802MN2
  • Home control features activate lights, appliances, garage doors and numerous other devices
  • The VISTA Interactive Phone Module (4286 VIP) gives the end-user control of the system from any touchtone phone; and responds in English, with over a 100 word vocabulary
  • Full English display keypads for clear understanding of system status and zone locations
  • Openings, closings, alarm and trouble messages can be sent directly to a pager, allowing system status to be confirmed; parents can use this feature to verify that their children have arrived home

Hardwired Expansion Devices

  • 4219 - eight hardwired zones - 16mA
  • 4204 up to 4 relays - 15mA standby (each active relay draws an additional 40mA)
  • 4229 - eight hardwired zones and two relays  -36mA
  • Keypads
    — 6139 custom English (required for programming) - 100mA
    — 6128 fixed English LCD - 85mA/40mA
  • Voice module 4285 VIP - 160mA
  • Four wire smoke detectors
  • Keyswitch device - 4146 keyswitch

Wireless Receiver Systems

  • 5800 Series 
    — 5881L up to 8 zones - 50mA
    — 5881M up to 16 zones - 50mA
    — 5881H up to 30 zones - 50mA
  • All Receivers Support
    — Diversity reception with two antennae
    — Remote mounting for best location
    — Unique supervision and low battery indications by point

Transmitters

  • 5800 Series
    — Three volt Duracell lithium batteries
    —One mile range
    — Tamper standard
  • UL Residential Fire & Burglary and CFM


Vista-40
DISCONTINUED
 

  • Nine hardwired zones, expandable to 64 zones
  • Two partitions with seven authority levels
  • 70 user codes
  • 100 event alarm history log
  • Two-way downloading
  • Supports 16 two-wire smoke detectors and 16 keypads
  • Three technology options:
    — Standard hardwired, expander 4208U (8 zones) 4190WH (2 zones)
    — ADEMCO polling loop addressable devices
    — Wireless (5800 series)
  • Supports up to eight relays
  • Supports X-10 transformer (Part No. 4300)
  • Long Range Radio triggers (four)

Control features of the VISTA-40

  • Wireless remote controls (featuring single button system operation):
    — 5804 - Four button programmable wireless key
    — 5804BD - Bi-directional four-button programmable wireless key with system status feedback
  • Single or dual-button wireless personal panic:
    – 5802MN
    – 5802MN2
  • Home automation activates lights, appliances, garage doors, and numerous other devices
  • The Vista Interactive Phone Module (VIP) gives the end-user control of the system from any touchtone phone; the 4286 VIP responds in clear English, with over a 100 word vocabulary
  • Full English display keypads clearly communicate system status and zone locations

Output Control

  • Supports up to two relay boards (Part No. 4204)
  • Each relay board supports four relays for a total of eight
  • Optional X-10 transformer/interface (part number 4300) may be used to control X-10 receiving devices

Zones

  • Nine hardwired zones
  • Selectable response on zone 9:
    10msec or 500msec
  • Assignable to either partition
  • 14 zone types to choose from
  • Programmable swinger suppression
  • Expandable to 64 zones using 5800 wireless, or hardwired expansion

Hardwired Expansion Devices

  • 4208U up to eight zones - 25mA
  • 4204 up to eight relays - 15mA (each active relay draws 40mA)
  • Powerline support - 4300 transformer/interface
  • Keypads
    – 6139 custom English (required for programming) - 100mA
    – 6128 fixed English LCD - 30m
  • Voice Module 4286VIP - 160mA
  • Two-wire smoke detectors
  • V-Plex™ polling loop devices and keyswitch devices

Wireless Receiver Systems

  • 5800 Receivers
    – 5881ENL up to 8 zones - 50mA
    – 5881ENM up to 16 zones - 50mA
    – 5881ENH up to 64 zones - 50mA
  • All receivers support:
    – Diversity reception with two antennas
    – Remote mounting for best location
    – A second receiver for maximum coverage or tough installations
    – Unique supervision and low battery indications by point

Transmitters

  • 5800 Series - three volt lithium batteries, one mile range, tamper standard
  • UL Residential Fire and Burglary and CFM

  • Commercial Burglary (with VISTA-UL kit)


Vista-50P

 

  • Nine hardwired zones standard
  • Expandable to 87 total zones
  • Eight partitions standard
  • 75 user codes work in all partitions
  • Seven authority levels
  • 224 event memory log/printer option
  • Four  trigger outputs
  • 5800 wireless compatibility
  • Supports two-wire multiplex
  • Scheduling of events (real time clock)
  • Keypad macro features
  • Master console option for viewing all partitions at a glance
  • Common lobby logic
  • Fast downloading
  • Supports up to 16 relays and/or X-10
  • Quick start programming
  • False alarm features
  • UL Commercial Burglary listed (VISTA-50PUL)

Control features of the VISTA-50P

  • Wireless remote controls (featuring single button system operation):
    — 5804 - Four Button Wireless Key
    — 5804BD - Bi-Directional Four-Button Wireless Key with system status feedback
  • Single or dual-button wireless personal panic:
    — 5802MN - 5802MN2
  • Home control features activate lights, appliances, garage doors, and numerous other devices
  • The VISTA Interactive Phone Module (VIP) gives the end user control of their system from any touchtone phone. The 4286 VIP responds in English, with a vocabulary of over 100 words
  • Full English display keypads for clear understanding of system status and zone locations
  • Timed event applications:
    — Opens garage doors and turns on lights
    — Provides that "lived-in look" while away from home
    — Ability to limit access to parts of the home at certain times

Output Control

  • Supports up to four relay boards (Part No. 4204)
  • Each board supports four relays for a total of 16
  • Optional X-10 interface (Part No. 4300) may be used to control X-10 receiving devices
  • Each X-10 receiver address counts as one relay when computing total relays
  • Real time clock can be used for relay/X-10 control

Hardwired Expansion Devices

  • 4208U Eight-Zone Expansion Module
  • Keypads
    — 6139 Custom English (required for programming) -100mA
    — 6128 Fixed English LCD - 30mA
  • 4286 VIP Voice Module -160mA
  • Two-wire Smoke Detectors
  • Duct Detectors
  • Serial Printer
  • V-Plex™ Polling Loop Devices
  • Key Switch Devices

Wireless Receiver Systems

  • 5800 Series
    — 5881ENL up to 8 zones-50mA
    — 5881ENM up to 16 zones-50mA
    — 5881ENH up to 86 zones-50mA
  • All Receivers Support
    — Diversity reception with two antennas
    — Remote mounting for best location
    — Use of second receiver for maximum coverage or tough installations
    — Unique supervision and low battery indications by point

Transmitters

  • 5800 Series
    — Three-volt Duracell lithium batteries
    — One mile range
    — Tamper standard
  • UL Residential Fire and Burglary and CSFM

  • UL Commercial Burglary (VISTA-50PUL)


 

   
© Copyright 1997 - 2010

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 08-Jun-2010
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 *  etc...  etc....

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US