ALARMSBC LOGO---back to home page

ADEMCO WIRELESS EQUIPMENT

THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY


MESSAGE
BOARD


FREE USER
MANUALS


ALARM
COMPANIES

Alarm Installation 
P. I.
Patrol Services  
Central Stations
Fire Alarm  
Locksmith


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

Wireless_Devices 
Central  Station
Equipment

CCTV
Fire Alarm
Gas/CO-Detectors
Dual Detectors
Glass Break Detector 
PIR (motion detector)
Environmental
Magnetic Contacts
Transformers
Batteries
Siren  

Discontinued
Items


POINTS
of
INTEREST
 

Metric Imperial US Conversion
Frequently Asked Question
Statistics
How  Devices Works
Y2K


FALSE ALARMS

False Alarms Fees
British Columbia
California
Other US Cities


FREE  LINK
TO
 AlarmsBC

 


Our Guestbook


CONTACT US

Designed for a quick install, the LYNXR incorporates a control panel, keypad, siren and dialer in one sleek and supports all 5800 wireless devices and sensors.

Designed for a quick install, the LYNXR incorporates a control panel, keypad, siren and dialer in one sleek and supports all 5800 wireless devices and sensors.

Residential Features Comparison Chart

 

Designed for a quick install, the LYNXR incorporates a control panel, keypad, siren and dialer in one sleek and supports all 5800 wireless devices and sensors.

Powerful features to satisfy demanding installations

  • 24 wireless zones of protection and one hardwired zone
  • Four wireless keys that don’t require zones
  • Supports 5804 Watch
  • Real time clock
  • Full 16-button keypad with easy to read LCD display and status LEDs
  • Built-in two-way voice system
  • Wall or optional desk-top mounting
  • 85db internal sounder with voice siren
  • Internal speaker and microphone
  • Supports up to eight X10 devices
  • Eight user codes
  • 84 event log
  • Fully downloadable
  • Rechargeable battery backup
  • Scheduling
  • Voice Siren

 

   

 

End users will appreciate the easy to use convenience and control features of the LYNXR-EN

  • Full voice response
  • Family message center that records and plays back voice messages
  • Speakerphone operation
  • Remote phone control
  • Bi-directional remote provides system status feedback
  • Wireless, programmable remotes offer single-button system control
  • Activate lights, appliances, garage doors, and numerous other applications with the touch of a button or at specified times
  • Quick exit that enables users to leave the house for a brief time without disarming the system
  • Chime by zone, sounds chime and speaks location in plain English
  • Paging capability for openings, closings, alarm and trouble messages; parents can use this feature to verify that their children have arrived home
  • Single button operation, including paging

General Specifications

  • Full function keypad with LCD display
  • Built-in X-10 capability
  • Family message center with voice recording and playback
  • Single button operation
  • Paging
  • Multiple default settings for easy programming
  • Full voice response
  • Remote downloading
  • Eight user codes
  • 84 event log
  • Chime by zone
  • Quick exit
  • Real-time clock
  • Scheduling
  • Rechargeable battery backup
  • RF enrollment speeds installation of wireless keys and transmitters

Electrical

  • Voltage Input: 9VAC from plug-in 15VA transformer
  • Rechargeable Backup Battery : Six 1.2-volt/cell nickel-metal hydride rated at 1100mA
  • Alarm Sounder: 
    – Piezo = 6-14VDC, 30mA max
    – Bell = 6-14VDC, 120mA max (e.g., ADEMCO’s WAVE2EX)
  • Long Range Radio: Rated 12mA@ 12-volt nominal (negative trigger signal)
  • LYNXR-EN receiver supports
    – 24 zones and four wireless keys
    – Two-way wireless devices with status feedback: 5804BD and 5827BD
    – Diversity reception with two antennae
    – Indications by zone and low battery indicator

Communications

  • Formats supported:
    – ADEMCO Express: 10 characters/sec, DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400H KISSOFF
    – ADEMCO Contact ID Reporting: 10 characters/sec., DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF
    – ADEMCO Low Speed: 10 pulses/sec, 1900Hz Data Tone, 400Hz ACK/KISSOFF
    – Radionics/SESCOA: 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Can report 0-9, B-F.
  • Line Seize: Double Pole
  • Ringer Equivalence: 0.6B
  • FCC Registration No.: 5GBUSA-25623-AL-E

Maximum Zone 1 Resistance

  • 300 ohms, excluding 2k ohm EOLR

Physical Dimensions

  • Width: 10-3/8"
  • Height: 7-1/8"
  • Depth: 1-3/4"


AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


JOKES


DAILY NEWS


CANADA MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


CONTACT US

 

 

  
© Copyright 1997-
2008
Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 23-Mar-2008
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US