ALARMSBC LOGO---back to home page

ADEMCO EQUIPMENT


MESSAGE
BOARD


FREE USER
MANUALS

English
International
Chinese


ALARM
COMPANIES

Canada
USA
UK
Australia
New Zeeland


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

-Wireless Devices 
-Central  Station
Equipment

-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector 
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren  

Promotion
Special Orders
&
ON SALE

Items


POINTS
of
INTEREST
 

-Metric Imperial US Conversion
-Frequently Asked Question
-Security Licence
-Statistics
-Standards
-How  Devices Works
-Tips to Improve Security
-Y2K


FALSE ALARMS

-False Alarms Fees
-British Columbia
-California
-Other US Cities


CENTRAL STATION


INSTALLATION
&
SERVICE


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


FREE  LINK
TO
 AlarmsBC


JOKES


DAILY NEWS


CANADA
MAP

 


BRITISH
COLUMBIA
MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


Our Guestbook


CONTACT US

 

 

COMMERCIAL BURG/FIRE CONTROL PANELS
VISTA-5110XM     
 


5110XM
vista 5110 xm
 The 5110XM is a UL Listed, microprocessor based fire alarm control/communicator that supports five hardwired zones. It may be used as a slave Digital Alarm Communicator Transmitter (DACT) providing central or remote station service for a central or remote station listed Fire Alarm Control Panel (FACP). It may also be used as a stand alone non-coded local, central station or remote station control.
The model 5110XM is fully supervised and supports one two-wire smoke detection circuit and four-wire smoke detectors on all five circuits. Its powerful microprocessor continuously monitors and reports system status of AC, standby battery, zone inputs and telephone line connections. In the event of a fault condition a local audible sound is activated as well as reporting directly to central station.

FEATURES

  • Five supervised style B zones
  • One master code
  • Five user codes
  • Seven built-in LED indicators
  • One notification appliance circuit
  • Temporal code compliant
  • Supervised digital dialer
  • Optional panel door mounted silence/reset switch when AHJ approved
  • Supports two-wire compatible smoke detector
  • Supports up to four keypads
  • Backup digital dialer built in
  • Auxiliary form "C" relay
  • Built-in warning buzzer
  • Programmable via 6139R alpha keypad or downloader
  • Supports major communication formats
  • UL864 Listed
  • NFPA 72 compliant
  • MEA Approved
  • Upload/Download capable

APPLICATIONS

The 5110XM Fire Alarm Communicator (DACT - Digital Alarm Communicator Transmitter) is well suited for a variety of applications a stand alone fire control or slave DACT. A diverse line of ADEMCO alarm notification appliances as well as initiating devices supports this powerful control panel. Some of the applications supported are monitoring of sprinkler supervisory or waterflow switches in factory or warehouse environments, fast food chains, department stores, retail stores, library and museums as well as professional and office buildings. This panel complies with the new, June 1,1998 NFPA requirement to alternate testing of dual phone lines on a rotating basis.

INSTALLATION

The 5110XM Fire Alarm Communicator (DACT) has been designed to mount both quickly and easily. It meets all applicable requirements for UL Commercial Fire installations. Remotely program and troubleshoot this panel via ADEMCO’s Windows™ based Compass Downloader.

Electrical:

Primary power 20VAC, 60Hz, 600mA max
Secondary
rated 18VAC, 40VA

Quiescent panel current draw:155mA

Backup battery:12VDC, 7AH min to 14AH max ,Lead acid battery (gel type)

Charging voltage:1 3.7VDC, nominal

Alarm power:12VDC, 1.0A max for notification (bell) output

Aux. standby power:12VDC,350mA max

Total power:1.0A from all sources

Aux. relay output: Type: Form C

Standby time:24 hours with 1A standby load or 60 hours with 210mA max standby load using 14AH battery

Fusing: Battery input, aux. and notification (bell) appliance circuits are protected using PTC circuit protectors. All outputs are power limited

Dialers:
Line seize:Double Pole
Ringer equiv.: 0.7B

Formats:

ADEMCO Low Speed, ADEMCO 4+2 press, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics

Mechanical: Cabinet dimensions —14.5"H X 1 2.5"W X 3"D

Environmental: -10°C to 70°C

Operating temp: 0°C to 50°C

Humidity: 85% RH

EMI:

  • Meets or exceeds the following requirements:
    —FCC Part 15, Class B Device
    —FCC Part 68
    —IEC EMC Directive

AGENCY LISTINGS

The 5110XM has been listed and approved for use in commercial fire applications. It has been listed under the following agency approvals:

Fire

  • UL864/NFPA72 Central and Remote Station DACT and Local, Central Station and Remote Station Control
  • Factory Mutual
  • California State Fire Marshall
  • MEA

Description

5110XM - Fire Alarm Communicator and DACT

5110XM-PAK1 - Consists of: 5110XM and 6139R - red alpha keypad

   
© Copyright 1997- 2010

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 08-Jun-2010
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 *  etc...  etc....

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US