FEATURES
-
Supports addressable V-Plex access
control points using VistaKey (1 to 8 doors)
-
Supports up to 15 doors of access
control using VISTA Gateway Module (VGM)*
-
Supports CCTV applications with the new
VistaView-100 CCTV switcher module
-
Identifies the point or zone of a fire
or alarm, using the new FSA-8/FSA-24 Fire system annunciator
-
Stores up to 512 events and can
accommodate 150 user codes
-
New E2 software simplifies programming
-
Easily programmed and maintained with
newly upgraded Compass Downloader software
-
Eight hardwired zones standard,
expandable to 120 V-Plex addressable points/zones or 128
wireless points/zones
-
Can control eight separate areas
independently (8 partitions)
-
Two on-board notification (bell)
circuits delivering 2.3A @ 12V or 3.4 amp @ 24V
-
Automatic smoke detector sensitivity
maintenance testing
* Connects to Northern Computers Passpoint
Access Control Systems. Maximum 32 doors
- Notification Appliance Circuit's (two)
— Programmable
— Temporal code compliant
— Individually silenceable
- Programmable on-board auxiliary relay
- SIA false alarm reduction features:
— Exit error logic
— Exit delay reset
— Cross zoning
— Call waiting defeat
— Recent close report
- Supports commercial hardwired, addressable V-Plex polling
loop and wireless zones
- Hardwired zones
— Provides eight style B hardwired zones
— EOLR supervised for Fire and UL burglary installations
— Supports N.O or N.C. sensors
— Individually assignable to one or all eight partitions
— Up to 16 two-wire smoke detectors each zone 1 and 2 (total
32)
— Up to 50 two-wire glassbreak detectors on zone eight
- Patented addressable V-Plex polling loop technology
— Supports up to 120 two-wire multiplex zones/points
— Global polling technology for faster processing
— Increased current draw capacity (128mA)
— Supervised by panel
— Individually assignable to partitions, notification
circuit (bell) output or aux relay
— 4,000 ft capability without the use of shielded cable
— Extender/Isolation bus module
— Two-wire smoke detector zone/group expansion module adds
two or four zones
— Eight zone - Class A and B extender module
— Eight zone - Class B extender module
— One zone supervised contact monitor module
- UL Listed wireless expansion
— Supports up to 128 wireless zones using 5881 receiver
— Supervised by control for check-in signals
— Tamper protection for transmitters
— Individually assignable up to eight partitions
— Supports UL268/NFPA listed wireless smoke detectors
- Access control integration
— Full integration with PassPoint Access Control System
Complete Gateway access functions
- Event reporting
- Local printer of access or VISTA related event
- Scheduled uploading of events to central station
- Stored events for one call retrieval
- Communication
— Phone mapping by zone response type
— Supports VIP Interactive Phone Voice Module
— Panel operation during download
— Uploading equipment list to central station
— Communication to PassPoint via VISTA Gateway Module (VGM)
EMI:
Meets or exceeds the following requirements:
— FCC Part 15, Class B Device
— FCC Part 68
— IEC EMC Directive
Burglary:
— UL609 Grade A Local Mercantile Premises and Mercantile
Safe and Vault
— UL611/1610 Grades A, AA, Central Station
— UL365 Grades A, AA Police Connect
Fire:
— UL864/NFPA72 Local, Central Station and Remote Station
— Factory Mutual
— California State Fire Marshal
— MEA
— UL985
Electrical:
Primary power: — 80VAC @ 72 VA ADEMCO No. 1450
Quiescent current draw:— 350mA
Backup battery:
— 12VDC, 12AH min to 34AAH max
— Lead acid battery (gel type)
Alarm power:— 12VDC, 1.7A max for
each notification (bell) circuit output
Aux. standby pwr:— 12VDC, 1A max
Total power:— 2.3A at 12VDC, 3.4A at
24VDC from all sources
Standby time:— 24 hours with 1A
standby load or 60 hours with 205mA max standby load using 34AAH
battery
Fusing:— Battery input, aux. and
notification (bell) circuit outputs are protected using PTC
circuit protectors. All outputs are power limited.
Main Dialer:
Line seize:— Double Pole
Ringer equiv.:— 0.713
Formats:
— ADEMCO Low Speed, ADEMCO 4+2 Express,
ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics
Auxiliary devices:
-
6160CR Alpha Keypad Commercial Fire
-
6139R - Red Alpha Keypad / Annunciator
-
FSA-8 & FSA-24 Fire System Annunciator
-
4204 - Relay Module, four form C contacts
-
4204CF - Two supervised output circuits
-
6220S - System printer used with 4100SM
Serial Interface Module
-
5140DLM, FSA-8, FSA-24, FSAKSM Fire
Annunciator
Two-wire and four-wire smoke detectors
conventional:
Horn/Strobes:
Manual pull stations:
V-Plex (addressable) devices:
-
4101SN Single Relay/Zone Module
-
4190SN Remote Point Module - two zones
-
4190WH Two Point Multiplex RPM
-
4193SN Two Zone Serial Interface Module
-
4208U Loop Expansion Module - eight zones
-
4208SNF Class A/13 Expander Module
-
4209U Group Zoning Module - two/four zones
-
4293SN One Zone Serial Interface Module
-
4297 Isolation/Extender Module
V-Plex (addressable) smoke detectors:
Passive infrared detectors:
-
998MX
-
4275EX-SN
-
4278EX-SN
-
Quest 2260SN
V-Plex (addressable) contacts:
-
4939SN-WH
-
4944SN-WH
-
4959SN
Glassbreak detectors:
VISTA Interactive Phone Module
Optional 24V power supply
Long range radio:
Upgraded software:
Wireless devices:
-
5804 - Wireless Key
-
5804BD - Bi-Directional Key
-
5804BDV - Bi-Directional with voice
-
5816 - Door/Window Transmitter
-
5819 - Shock Sensor
-
5827BD - Bi-Directional Keypad
-
5849 - Glassbreak Detector
-
5881 Series - RF Receiver supporting 5800
wireless detectors
-
5890 - PIR
Access control:
-
VistaKey V-Plex (addressable) Access Control
-
VistaKey-SK Starter Kit
-
VistaKey-EX Expansion Kit
-
VGM Vista Gateway Module to PassPoint Access
Control (Northern Computers)
CCTV:
Commercial wireless devices:
-
5869 - Hold up Transmitter
-
5817CB - Wireless Commercial Transmitter
-
5881ENHC - Commercial Fire/Burg Receiver
-
5808LST - Wireless Smoke Detector
-
5809 - Wireless Heat Detector
|