ALARMSBC LOGO---back to home page

ADEMCO EQUIPMENT

THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY


MESSAGE
BOARD


FREE USER
MANUALS


ALARM
COMPANIES

Alarm Installation 
P. I.
Patrol Services  
Central Stations
Fire Alarm  
Locksmith


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

Wireless_Devices 
Central  Station
CCTV
Fire Alarm
Gas/CO-Detectors
Dual Detectors
Glass Break Detector 
PIR (motion detector)
Environmental
Magnetic Contacts
Transformers
Batteries
Siren  

Discontinued
Items


POINTS
of
INTEREST
 

Metric Imperial US Conversion
Frequently Asked Question
Statistics
How  Devices Works
Y2K


FALSE ALARMS

False Alarms Fees
British Columbia
California
Other US Cities


FREE  LINK
TO
 AlarmsBC

 


Our Guestbook


CONTACT US

COMMERCIAL BURG/FIRE CONTROL PANELS
VISTA-128 FB    
 


VISTA-128 FB 

diagram

 Commercial Fire/Burg/CCTV and Access Control Platform

Designed to integrate seamlessly with CCTV, access control and ADEMCO's full range of fire and burglary components, the VISTA-128FB provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and addressable V-Plex  technologies. A diverse line of ADEMCO initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays support this extremely powerful control platform.
The VISTA-128FB has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. 

FEATURES

  • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors)

  • Supports up to 15 doors of access control using VISTA Gateway Module (VGM)*

  • Supports CCTV applications with the new VistaView-100 CCTV switcher module

  • Identifies the point or zone of a fire or alarm, using the new FSA-8/FSA-24 Fire system annunciator

  • Stores up to 512 events and can accommodate 150 user codes

  • New E2 software simplifies programming

  • Easily programmed and maintained with newly upgraded Compass Downloader software

  • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones

  • Can control eight separate areas independently (8 partitions)

  • Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4 amp @ 24V

  • Automatic smoke detector sensitivity maintenance testing

* Connects to Northern Computers Passpoint Access Control Systems. Maximum 32 doors

  • Notification Appliance Circuit's (two)
    — Programmable
    — Temporal code compliant
    — Individually silenceable
  • Programmable on-board auxiliary relay
  • SIA false alarm reduction features:
    — Exit error logic
    — Exit delay reset
    — Cross zoning
    — Call waiting defeat
    — Recent close report
  • Supports commercial hardwired, addressable V-Plex polling loop and wireless zones
  • Hardwired zones
    — Provides eight style B hardwired zones
    — EOLR supervised for Fire and UL burglary installations
    — Supports N.O or N.C. sensors
    — Individually assignable to one or all eight partitions
    — Up to 16 two-wire smoke detectors each zone 1 and 2 (total 32)
    — Up to 50 two-wire glassbreak detectors on zone eight
  • Patented addressable V-Plex polling loop technology
    — Supports up to 120 two-wire multiplex zones/points
    — Global polling technology for faster processing
    — Increased current draw capacity (128mA)
    — Supervised by panel
    — Individually assignable to partitions, notification circuit (bell) output or aux relay
    — 4,000 ft capability without the use of shielded cable
    — Extender/Isolation bus module
    — Two-wire smoke detector zone/group expansion module adds two or four zones
    — Eight zone - Class A and B extender module
    — Eight zone - Class B extender module
    — One zone supervised contact monitor module
  • UL Listed wireless expansion
    — Supports up to 128 wireless zones using 5881 receiver
    — Supervised by control for check-in signals
    — Tamper protection for transmitters
    — Individually assignable up to eight partitions
    — Supports UL268/NFPA listed wireless smoke detectors
  • Access control integration
    — Full integration with PassPoint Access Control System Complete Gateway access functions
  • Event reporting
  • Local printer of access or VISTA related event
  • Scheduled uploading of events to central station
  • Stored events for one call retrieval
  • Communication
    — Phone mapping by zone response type
    — Supports VIP Interactive Phone Voice Module
    — Panel operation during download
    — Uploading equipment list to central station
    — Communication to PassPoint via VISTA Gateway Module (VGM)

EMI:
Meets or exceeds the following requirements:
— FCC Part 15, Class B Device
— FCC Part 68
— IEC EMC Directive

Burglary:
— UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
— UL611/1610 Grades A, AA, Central Station
— UL365 Grades A, AA Police Connect

Fire:
— UL864/NFPA72 Local, Central Station and Remote Station
— Factory Mutual
— California State Fire Marshal
— MEA
— UL985

Electrical:
Primary power: — 80VAC @ 72 VA  ADEMCO No. 1450

Quiescent current draw:— 350mA

Backup battery:

— 12VDC, 12AH min to 34AAH max
— Lead acid battery (gel type)

Alarm power:— 12VDC, 1.7A max for each notification (bell) circuit output

Aux. standby pwr:— 12VDC, 1A max

Total power:— 2.3A at 12VDC, 3.4A at 24VDC from all sources

Standby time:— 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34AAH battery

Fusing:— Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited.

Main Dialer:
Line seize:— Double Pole
Ringer equiv.:— 0.713

Formats:

— ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics

Auxiliary devices:

  • 6160CR Alpha Keypad Commercial Fire

  • 6139R - Red Alpha Keypad / Annunciator

  • FSA-8 & FSA-24 Fire System Annunciator

  • 4204 - Relay Module, four form C contacts

  • 4204CF - Two supervised output circuits 

  • 6220S - System printer used with 4100SM Serial Interface Module

  • 5140DLM, FSA-8, FSA-24, FSAKSM Fire Annunciator

Two-wire and four-wire smoke detectors conventional:

  • System Sensor smoke detectors

Horn/Strobes:

  • System Sensor notification appliances

Manual pull stations:

  • 5140MPS-1

  • 5140MPS-2

V-Plex (addressable) devices:

  • 4101SN Single Relay/Zone Module

  • 4190SN Remote Point Module - two zones

  • 4190WH Two Point Multiplex RPM

  • 4193SN Two Zone Serial Interface Module

  • 4208U Loop Expansion Module - eight zones

  • 4208SNF Class A/13 Expander Module

  • 4209U Group Zoning Module - two/four zones

  • 4293SN One Zone Serial Interface Module

  • 4297 Isolation/Extender Module

V-Plex (addressable) smoke detectors:

  • 5192SD

  • 5192SDT

Passive infrared detectors:

  • 998MX

  • 4275EX-SN

  • 4278EX-SN

  • Quest 2260SN

V-Plex (addressable) contacts:

  • 4939SN-WH

  • 4944SN-WH

  • 4959SN

Glassbreak detectors:

  • 9500SN

VISTA Interactive Phone Module

  • 4286 Voice Module

Optional 24V power supply

  • PS24 - 24V power supply - 3.4A

Long range radio:

  • Long range radio 7720ULF-XX, 7845C, 7835CFPK

Upgraded software:

  • Upgraded Compass Downloader Windows compatible

Wireless devices:

  • 5804 - Wireless Key

  • 5804BD - Bi-Directional Key

  • 5804BDV - Bi-Directional with voice

  • 5816 - Door/Window Transmitter

  • 5819 - Shock Sensor

  • 5827BD - Bi-Directional Keypad

  • 5849 - Glassbreak Detector

  • 5881 Series - RF Receiver supporting 5800 wireless detectors

  • 5890 - PIR  

Access control:

  • VistaKey V-Plex (addressable) Access Control

  • VistaKey-SK Starter Kit

  • VistaKey-EX Expansion Kit

  • VGM Vista Gateway Module to PassPoint Access Control (Northern Computers)

CCTV:

  • VistaView-100-CCTV Switch Module

Commercial wireless devices:

  • 5869 - Hold up Transmitter

  • 5817CB - Wireless Commercial Transmitter

  • 5881ENHC - Commercial Fire/Burg Receiver

  • 5808LST - Wireless Smoke Detector 

  • 5809 - Wireless Heat Detector

 


AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


JOKES


DAILY NEWS


CANADA MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


CONTACT US

 

  
© Copyright 1997- 2008

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 20-Jan-2008
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US