Key Features
-
Eight zones standard expandable to 87
zones/points
-
Eight partitions
-
150 user codes, 224 event log capacity
-
Two on-board notification (bell) circuits
delivering 2.3A at 12V or 3.4A at 24V (optional)
-
Supports in excess of 1,000 two-wire smoke
detectors
-
Seven authority levels
-
Temporal code compliant
-
Supports UL268 Listed commercial wireless
smoke detectors
-
Supervised dialer circuit
-
Event logging storage, printing and retrieval
-
Automatic scheduling features
-
Easily programmed and maintained through
Compass Windows based software
-
Programmable auxiliary Form C relay
-
Hardwired, wireless and V-Plex (addressable)
technology
-
Uses existing wiring for retrofit applications
Additional Features
-
Notification Appliance Circuits (Two)
Programmable
Temporal code compliant
Individually silenceable
-
Programmable on-board auxiliary relay
-
SIA false alarm reduction features:
Exit error logic
Exit delay reset
Cross zoning
Call waiting defeat
Recent close report
-
Supports hardwired, V-Plex (addressable)
polling loop and wireless zones
-
Hardwired zones
Provides eight style B hardwired zones
EOLR supervised for Fire and UL burglary installations
Supports N.O. or N.C. sensors
Individually assignable to one or all eight partitions
Up to 16 two-wire smoke detectors on zones one and two (32
total)
Four-wire smoke or heat detectors on zones one to eight
Up to 50 two-wire glass break detectors on zone eight
-
Patented V-Plex (addressable) polling loop
technology
Supports up to 120 two-wire multiplex zones/points
Can use existing wiring
Global polling technology for faster processing
Increased current draw capacity (128mA)
Individually assignable to partitions, notification
circuit (bell) output or aux relay
4,000 ft capability without the use of shielded cable
Extender/Isolation bus module
Two-wire smoke detector zone/group expansion module adds
two or four zones
Eight zone - Class A and B extender module
Eight zone - Class B extender module
One zone supervised contact monitor module
-
UL Listed wireless smoke detector expansion
Supports up to 87 wireless zones using 5881 receiver
Supervised by control for check-in signals
Tamper protection for transmitters
Individually assignable up to eight partitions
Supports UL864/NFPA listed/complaint wireless smoke
detectors
-
Scheduled uploading of events to central
station
Auxiliary devices:
6139R - Red
Alpha Keypad/Annunciator
5140DLM - Backup Dialer Module
5140LED - LED Annunciator Module
4204 Relay Module, four Form C contacts
4204CF Two supervised output circuits
5881 EH RF Receiver supporting 5800 wireless detectors
6220S System Printer used with 4100SM Serial Module
Two-wire Smoke Detectors Conventional:
- 2100 Series Photoelectric
- 2400 Series Photoelectric
- 1100 Series Ionization
Four-Wire Smoke Detectors Conventional:
- 2112/24 Series Photoelectric
- 1412 Series Ionization
Horn/Strobes:
- System Sensor Notification Appliances
Manual Pull Stations:
V-Plex (addressable) Devices:
- 4101SN Single Relay /Zone Module
- 4190WH Remote Point Module - two zones
- 4193SN Two Zone Serial Interface Module
- 4208U Loop Expansion Module - eight zones
- 4208SNF Eight Zone/2 Class A/6 Class B Expander Module
- 4209U Group Zoning Module - two/four zones
- 4293SN One Zone Serial Interface Module
- 4297 Isolation/Extender Module
V-Plex (addressable) Smoke Detectors:
Passive Infrared Detectors:
V-Plex (addressable) Contacts:
- 4194WH
- 4939SN
- 4944SN
- 4959SN
Glassbreak Detectors:
Optional 24V Power Supply
- PS24 - 24V power supply - 3.4A
Long Range Radio:
Upgraded Software:
- Upgraded Compass Downloader Windows
compatible
Wireless Devices:
- 5804 - Wireless Key
- 5804BD Bi-Directional Key
- 5808 - Wireless Smoke Detector
- 5808C - Wireless Smoke Detector without sounder
- 5809 - Wireless Heat Detector
- 5816 Door/Window Transmitter
- 5819 Shock Sensor
- 5827BD Bi-Directional Keypad
- 5849 Glassbreak Detector
- 5890 PIR
Applications
The VISTA-100 control is well suited
for a variety of applications as an integrated fire and burglary
control. A diverse line of ADEMCO initiating and control devices
supports this extremely powerful control. Some of the applications
supported are: medical and professional buildings, supermarkets,
churches or synagogues, office buildings, schools, universities,
strip malls, and factory or warehouse environments.
Installation
The VISTA-100 alarm system has been
designed to mount both quickly and easily in an attack resistant
cabinet. It meets all applicable requirements for UL commercial
Fire and Burglary installations and is NFPA72 compliant.
ELECTRICAL
Primary Power 120VAC to ADEMCO No.
1451 Transformer Secondary rated 18VAC, 72VA
Quiescent Current Draw: 350mA
Backup Battery:
12VDC, 12AH min to 34.4AH max
Lead acid battery (gel type)
Alarm Power: 12VDC, 1.7A max for
each notification (bell) circuit output
Aux. Standby Power: 12VDC, 1A max
Total Power: 2.3A at 12VDC, 3.4A at
24VDC from all sources
Standby Time: 24 hours with 1A
standby load or 60 hours with 205mA max standby load using 34.4AH
battery
Fusing: Battery input, aux. and
notification (bell) circuit outputs are protected using PTC
circuit protectors. All outputs are power limited
Main Dialer:
Line Seize: Double Pole
Ringer Equiv.: 0.7B
Formats: ADEMCO Low Speed, ADEMCO 4+2
Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and
Radionics
Agency Listings
Burglary
- UL609 Grade A Local Mercantile Premises and Mercantile Safe
and Vault
- UL611/1610 Grades A, AA, Central Station
- UL365 Grades A, AA Police Connect
Fire
- UL864/NFPA72 Local, Central Station and Remote Station
- Factory Mutual (Pending)
- California State Fire Marshal
- MEA
- UL985
|