|
EQUIPMENT DSC
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Canada -Wireless
Devices Promotion -Metric Imperial
US
Conversion
-False Alarms Fees
=CENTRAL STATIONS
PROTOCOLS =DATA
CENTER and |
ALL 433 Mhz Wireless Devices: ( contacts, motion detector, panic pendant etc..) are compatible with 9047 , Envoy and all Power series and New Power Series Control Panels Incorporating esthetics seldom seen in the security industry, the PowerSeries 9047 features bold, contoured lines and enlarged keypad buttons that are easy to interpret and use. Also, despite occupying the smallest footprint of any self-contained wireless alarm system currently available, the PowerSeries 9047 is equipped with the industrys largest, full-message LCD display. Wireless Device Enrollment A simplified wireless device enrollment process greatly reduces overall installation times. Installers no longer need to manually program serial numbers or wireless attributes. Instead, a series of enrollment screens prompt installers to confirm Electronic Serial Numbers (ESN), zone numbers and zone type. If an installer attempts to enroll a device already recognized by the system, the keypad will identify it as a duplicate and display its assigned zone and ESN. Template Programming Programming the self-contained wireless alarm system is simplified through template programming. It allows installers to quickly program the functions required for basic operation by entering a 4-digit code. Code prompts exist for pre-defined zone definitions, reporting code formats, communication call directions, and DLS setup. Once the 4-digit code has been programmed, the installer is then prompted to enter the monitoring station telephone number and account code, DLS access code, entry and exit delays, and installer code. Compatibility The PowerSeries 9047 is compatible with all DSC 433 MHz wireless devices. Specifications Dimensions. . . . . . . . . . . . . . . . 5.4" x 8.07" x 1.53"(138 mm
x 205 mm x 39 mm) Audio Communication Esthetics aside, the PowerSeries 9047 also features instantaneous, 2-way audio VOX only or VOX and push-to-talk alarm communication with the monitoring station during alarm events through high-quality speakers and microphones. COMPARE 9047 WITH GE
SIMON3 AND HONEYWELL LYNX
|
© Copyright
1997- 2010
Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of
their respective companies or mark holders.
UPDATE
12-Feb-2010
MMC&S Inc.
MESSAGE BOARD *** ALARM COMPANIES *** FREE USER MANUALS
ALARM EQUIPMENT >>>
dsc *
ademco *
paradox *
fbi *
gas/co - detectors * wireless devices
* fire alarm
motion detectors *
dual detectors *
glass break detectors *
magnetic contacts *
transformers *
battery *
siren
Environmental *
central station
equipment * monitors *
cameras *
recorders *
switcher & quads
INSTALLATION / SERVICE / MONITORING
POINTS of
INTEREST
>>>
metric imperial us conversion
* frequently asked
question *
statistics
how the sensor works * y2k
* basic
security systems 101 *
etc... etc....
FALSE ALARMS >>> false alarms fees * British Columbia ( CANADA ) * California (USA) * other USA cities
LINK to AlarmsBC *** LINKS TO RELATED SITES *** SEARCHING WWW
WEB HOSTING * ** DATA CENTER *** HOSTING PLANS
JOKES *** DAILY NEWS *** GLOSSARY *** CANADA MAP
ALARM TECH
HELP >>> INSTALLATION
TIPS >>>
SENTROL
Application notes *
ULC
Installation tips
ULC Level of
protection *
Default Installer codes *
ADT alarm panel - Cross
Reference *
Network Cable
Simplified *
etc... etc....
CENTRAL STATIONS PROTOCOLS * TECH SUPPORT PHONE NUMBERS * SOFTWARE